Comparison of two different bicarbonate replacement fluids during CVVH with RCA: a prospective, randomized, controlled trial
Rattachement africain : at, gb. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
This study aimed to compare a high (HBF) and low (LBF) bicarbonate (HCO 3 − ) replacement fluid over 96 h after continuous veno-venous hemofiltration (CVVH) initiation using regional citrate anticoagulation to determine which fluid achieved better acid–base balance. In this prospective, randomized, controlled, open-label, cross-over, single-center trial, patients were randomized to initially receive either LBF (22 mmol/l HCO 3 − ) or HBF (30 mmol/l HCO 3 − ) for 48 h (first phase), followed by changing to the other fluid for a further 48 h (second phase). Intracorporeal pH and HCO 3 − changes were analyzed by calculating the rates of levels outside the standard values (excursion rates). Generalized estimating equations were performed to estimate the odds ratios for at least one pH/HCO 3 − excursion. Time to normalization within the first phase for pH and HCO 3 − was assessed using Kaplan–Meier curves and log-rank tests. A total of 88 patients were included. The rates for at least one pH and HCO 3 − excursion were higher in patients treated with HBF compared to LBF (pH: first phase 52% vs. 41%; second phase 48% vs. 34%; HCO 3 − : first phase 68% vs. 43%; second phase 73% vs. 43%). Adjusted odds ratios were 1.78 (95% CI 1.12–2.82; p = 0.015) for pH and 3.60 (95% CI 2.16–5.99; p < 0.001) for HCO 3 − . The time to normalization of pH in acidotic patients and of HCO 3 − in patients with low HCO 3 − did not differ significantly between HBF and LBF ( p = 0.102, p = 0.468). LBF showed significantly lower rates of pH and HCO 3 − excursions compared to HBF and no significant differences to the pH normalization in acidotic patients were observed. NCT04071171.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Comparison of two different bicarbonate replacement fluids during CVVH with RCA: a prospective, randomized, controlled trial
- Date Crossref
- 17/11/2025
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.