Impact of Dosimetric Parameters on Tumor Control in Stereotactic Radiotherapy for Pancreatic Cancer: A Prospective Study on 104 Patients Treated with Simultaneous Integrated Protection (SIP)
Rattachement africain : it. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: One of the challenges in treating pancreatic ductal adenocarcinoma (PDAC) with stereotactic radiotherapy (SRT) is to manage lesions abutted to the duodenum, bowel and stomach. Simultaneous integrated protection (SIP) is one of the proposed approaches to increase plan reproducibility and quality. However, no clinical data are available regarding the dosimetric objectives impacting local control probability. Methods: This is a prospective, single-arm study. Key inclusion criteria were as follows: PDAC histology; tumor abutment with duodenum, stomach, or small bowel; and SRT schedule consisting of 45 Gy in six fractions. Delineation of the PTV overlapped with critical OARs (PTV_SIP) and PTV outside critical OARs (PTV_Dominant) was mandatory. Dose constraints were as follows: (near) maximum dose, D2cc, and D20cc to critical OARs 38 Gy, 32 Gy, and 24 Gy, respectively. This study was designed to prospectively investigate the main clinical and dosimetric parameters impacting freedom from local recurrence (FFLR). Results: From June 2019 to January 2024, 104 patients were enrolled. One-year FFLR was 91.7%. Fifteen events of local failure occurred (17.6%). Mapping of local relapses showed a relapse inside the PTV_SIP area in nine patients and outside the PTV_SIP in six cases (NS). Whole PTV > 69 cc, PTV_SIP > 4 cc, PTV-SIP/whole PTV ratio > 7%, (near) Dmin to PTV_SIP < 25 Gy, mean dose to PTV_SIP < 28 Gy, and (near) Dmin to PTV_Dominant < 29 Gy were associated with worse FFLR. Multivariable analysis showed PTV_SIP absolute volume of more than 4 cc, mean dose to PTV_SIP < 28 Gy and whole PTV > 69 cc were independently related to worse FFLR. One case of acute G4 toxicity and two cases of acute G3 toxicity occurred, with two late toxicity deaths not certainly due to treatment. Conclusions: In this prospective study, SIP planning strategy with six fractions is safe and effective in pancreatic targets with critical contact with critical OARs. Given its potential advantages, SIP planning is a potential innovative strategy that should be compared to standard SRT planning in an ad hoc trial design.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Impact of Dosimetric Parameters on Tumor Control in Stereotactic Radiotherapy for Pancreatic Cancer: A Prospective Study on 104 Patients Treated with Simultaneous Integrated Protection (SIP)
- Date Crossref
- 10/11/2025
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.