Coil Sketching for Fast and Efficient 4D Lung MRI Reconstruction
Résumé fourni par la source
PURPOSE: To develop and evaluate a memory-efficient and accelerated reconstruction framework for respiratory-resolved 4D lung MRI using coil sketching and Toeplitz approximation, enabling high-quality motion-compensated low-rank (MoCo-LR) reconstructions on clinically accessible GPU hardware. THEORY AND METHODS: Respiratory-resolved 4D MRI enables non-invasive assessment of pulmonary structure and function but is limited by computational and memory demands from large matrices and long acquisitions. We extend the coil sketching framework-previously proposed for 3D imaging-to 4D (3D + time), allowing the data consistency term of compressed-sensing objective functions to be solved with reduced GPU memory consumption and reconstruction duration while preserving image accuracy. Additionally, we implement Toeplitz approximation to accelerate repeated applications of the normal encoding operator, further reducing computational demand. Finally, we outline a MoCo-LR regularization technique that uses only forward deformations, improving reconstruction stability over many iterations. Reconstructions were performed across several regularization schemes using a 3D stack-of-spirals acquisition and evaluated for memory footprint, speed, and image accuracy. RESULTS: The proposed 4D coil sketching method reduced memory usage by ˜3-fold compared to fully sampled reconstructions and enabled high-resolution MoCo-LR reconstructions in < 10 min on < 48 GB GPUs. Toeplitz approximation further reduced runtime with minimal impact on image quality. Compared to conventional coil compression, coil sketching preserved parenchymal signal and structural fidelity in low-SNR regions. CONCLUSION: Coil sketching and Toeplitz approximation provide a generalizable, hardware-efficient solution for 4D lung MRI reconstruction. These methods reduce computational barriers, improve reconstruction speed, and maintain image quality, offering a path toward broader clinical adoption of respiratory-resolved lung MRI.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.
- Titre Crossref
- Coil Sketching for Fast and Efficient <scp>4D</scp> Lung <scp>MRI</scp> Reconstruction
- Date Crossref
- 07/11/2025
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.