Aller au contenu principal
Accès ouvert déclaré 2026 article

Reliability assessment framework based on feature separability for pathological cell image classification under prior bias

0Citations signalées — pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Résumé fourni par la source

Background and objective: Prior probability shift between training and deployment datasets challenges deep learning-based medical image classification. Standard correction methods reweight posterior probabilities to adjust prior bias, yet their benefit is inconsistent. We developed a reliability framework identifying when prior correction helps or harms performance in pathological cell image analysis. Methods: We analyzed 303 colorectal cancer specimens with CD103/CD8 immunostaining, yielding 185,432 annotated cell images across 16 cell types. ResNet models were trained under varying bias ratios (1.1-20$\times$). Feature separability was quantified using cosine similarity-based likelihood quality scores, reflecting intra- versus inter-class distinctions in learned feature spaces. Multiple linear regression, ANOVA, and generalized additive models (GAMs) evaluated associations among feature separability, prior bias, sample adequacy, and F1 performance. Results: Feature separability dominated performance ($β= 1.650$, $p < 0.001$), showing 412-fold stronger impact than prior bias ($β= 0.004$, $p = 0.018$). GAM analysis showed strong predictive power ($R^2 = 0.876$) with mostly linear trends. A quality threshold of 0.294 effectively identified cases requiring correction (AUC = 0.610). Cell types scoring $>0.5$ were robust without correction, whereas those $<0.3$ consistently required adjustment. Conclusion: Feature extraction quality, not bias magnitude, governs correction benefit. The proposed framework provides quantitative guidance for selective correction, enabling efficient deployment and reliable diagnostic AI.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Reliability assessment framework based on feature separability for pathological cell image classification under prior bias
Date Crossref
01/09/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Sujets associés

AI in cancer detectionCell Image Analysis TechniquesDigital Imaging for Blood Diseases

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.