Performance of a Tube-bundle Heat Exchanger in a Rectangular-section Right-angle Bend Duct
Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Three-dimensional numerical simulations are conducted to elucidate the fundamental differences in hydrodynamics and heat transfer performance between heat exchangers arranged in confined rectangular-section right-angle bend ducts and those in straight ducts, with a specific focus on applications such as gas‑quenching furnaces. The effects of the tube-bundle arrangement and number of tube rows on the pressure drop (Δp) and heat‑transfer rate (Q) are examined under identical inlet conditions. Based on the performance differences, improved correlations are established for pressure drop and heat transfer performance applicable to rectangular bend ducts. The results demonstrate a definitive ordering of pressure drops: Δpss (staggered arrangement, straight duct) > Δpsi (in-line arrangement, straight duct) > Δpbi (in-line arrangement, bend duct) > Δpbs (staggered arrangement, bend duct), and a parallel hierarchy for heat‑transfer rates: Qₛₛ > Qₛᵢ > Qbᵢ > Qbₛ. Although staggered arrangements achieve only modest heat‑transfer gains over in-line arrangements, their marked reduction in pressure drop yields the optimal overall performance evaluation criterion. Both the friction factor fb and Nusselt number Nub of the bend duct increase with the number of tube rows, though their growth attenuates as the tube pitch decreases. These mechanistic insights lead to improved empirical correlations for predicting Δpb and Nub in bend ducts. Validations against simulation data show deviations within ±5%, effectively overcoming the limitations of straight-duct formulas in complex bend-duct geometries. These correlations provide a solid theoretical basis for optimizing the design and performance of bend-duct heat exchangers in confined spaces.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Performance of a Tube-bundle Heat Exchanger in a Rectangular-section Right-angle Bend Duct
- Date Crossref
- 01/01/2026
- Éditeur
- Academic World Research
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.