Aller au contenu principal
Accès ouvert déclaré 2025 article

Evaluating double-reading mammography for long-term surveillance in breast cancer survivors: a retrospective exploratory analysis from a single center

0Citations signalées — pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

PURPOSE: This exploratory analysis aims to assess the clinical feasibility of transitioning breast cancer (BC) survivors from intensive follow-up to a long-term surveillance strategy based on double-reading mammography within a population-based screening model. MATERIAL AND METHODS: Women who underwent BC surgery in 2013 and were followed for 10 years at a tertiary cancer center in Italy were retrospectively included. Recurrence rates and time to relapse were analyzed using the Kruskal-Wallis test and Chi-square test. Available follow-up mammograms were independently reviewed by three experienced radiologists, blinded to clinical information, using a positive/negative binary scale. Pathology served as the reference standard. Sensitivity, positive predictive value (PPV), and inter-reader agreement (Cohen's and Fleiss' κ) were calculated. Simulated double reading was analyzed using McNemar's test. A p value < 0.05 was considered statistically significant. RESULTS: Among 505 women, 46 (9.1%) experienced BC recurrence: 19/271 (7.0%) in Luminal A, 6/84 (7.1%) in Luminal B, 3/28 (10.7%) in triple-negative (TN), 7/57 (12.3%) in HER2-positive (HER2 +) cancers, and 11/65 (16.9%) in ductal carcinoma in situ (DCIS), which showed the highest recurrence rate (p = 0.0024). Median time to relapse ranged from 4.7 years (TN) to 8.1 years (Luminal A), with no statistically significant difference among the subtypes (p = 0.190). Individual reader sensitivity ranged from 67.7 to 74.2%, increasing to 77.4-83.9% with double reading. PPVs ranged from 95.4 to 100% for single reading and from 96.0% to 96.2% for double reading. Differences in sensitivity and PPV between single and double reading were not statistically significant (p = 1.0). Five recurrences (16.1%) were mammographically occult and clinically detected. Inter-reader agreement was moderate to good (Cohen's κ = 0.38-0.69; Fleiss' κ = 0.57). CONCLUSIONS: Double-reading mammography showed a higher detection rate of BC recurrences compared to single reading in this exploratory setting, suggesting its potential role as a long-term surveillance strategy for BC survivors. However, the occurrence of relapses outside the mammographic field of view warrants careful consideration.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Evaluating double-reading mammography for long-term surveillance in breast cancer survivors: a retrospective exploratory analysis from a single center
Date Crossref
06/11/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Digital Radiography and Breast ImagingGlobal Cancer Incidence and ScreeningBreast Lesions and Carcinomas

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.