Aller au contenu principal
Accès ouvert déclaré 2025 preprint

Highly Efficient Coreactant-Free Electrochemiluminescence Sensing Platform Using Novel Microfabricated Multiplexed Entwined Spiral Microelectrodes for Point-of-Care Applications

0Citations signalées — pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Luminol-based Electrochemiluminescence (ECL) generates weak signals in neutral media and typically requires H 2 O 2 as a coreactant. However, H 2 O 2 instability and the need for on-site addition hinder real-time diagnostic applications. Compact integrated sensing platforms are ideal for point-of-care (POC) testing due to portability, low sample requirements, and multiplexing. However, as sensor dimensions decrease, the low light emission issue in ECL becomes severe. We introduce a novel fully integrated miniaturized silicon device consisting of three sensors comprised of unique entwined micro-spiral electrodes in a generator-collector configuration. This enables highly sensitive, coreactant-free multiplexed sensing at physiological pH by accelerating in-situ reactive oxygen species production and boosting ECL intensity. Systematic optimization of electrode geometry (gaps and widths) yields an 11-fold improvement in ECL signal compared to a single-electrode setup, as well as excellent reproducibility and stability. In addition to Trolox and H 2 O 2 detection, the platform demonstrates multiplex immunosensing through selective functionalization of the collector electrodes with chitosan nanocomposites, followed by Protein A/G-assisted immobilization of anti-IgG antibodies with peptide-based antifouling. The immunosensors exhibit high analytical performance (linear range: 0.001-100 pg·mL -1 , detection limit: 0.8 fg·mL -1 ) with excellent reproducibility and reliability in 25% fetal bovine serum, highlighting the platform’s potential for sensitive, coreactant-free multi-analyte POC diagnostics.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Highly Efficient Coreactant-Free Electrochemiluminescence Sensing Platform Using Novel Microfabricated Multiplexed Entwined Spiral Microelectrodes for Point-of-Care Applications
Date Crossref
06/11/2025
Éditeur
Wiley
Type
posted-content

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Advanced biosensing and bioanalysis techniquesElectrochemical Analysis and ApplicationsElectrochemical sensors and biosensors

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.