Felt Versus Pericardium for the Sandwich Technique in Type A Aortic Dissection: A Human Cadaver Study
Rattachement africain : at. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: The Sandwich technique is a commonly adopted method for reinforcing the dissected aortic wall during acute Type A aortic dissection (ATAAD) repair, using either felt or bovine pericardial strips. However, complications such as anastomotic bleeding, distal anastomotic new entry (DANE) and persistent false lumen (PFL) remain major challenges. This study evaluated and compared the sealing efficacy of felt versus pericardium in a human cadaver model. Methods: ATAAD was simulated in 20 fresh human cadavers. Repairs were performed using the sandwich technique with either felt (n = 10) or pericardium (n = 10), followed by end-to-end prosthetic graft anastomosis. Procedure time was recorded. Following the repair, the aortas were perfused at 160/90 mmHg using a glycerol-water solution to assess fluid leakage (mL), DANE and PFL. Results: Median leakage was significantly lower in the pericardium group (67.5 mL [IQR 40–198.8]) compared to the felt group (315 mL [IQR 285–445], p = 0.002). Procedure times were comparable between groups. DANE occurred in 20% (pericardium) and 30% (felt) of cases, while PFL was observed in 30% of cases in both groups; differences were not statistically significant. Conclusions: The superior sealing properties of pericardium in this study suggest a promising approach for reducing leakage in ATAAD repair. While rates of DANE and PFL were comparable, the advantage of pericardium was confined to leakage reduction. These findings highlight the need for further research to determine whether this experimental benefit translates into improved clinical outcomes.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Felt Versus Pericardium for the Sandwich Technique in Type A Aortic Dissection: A Human Cadaver Study
- Date Crossref
- 31/10/2025
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Medical University of Vienna Division of Anatomy pays non établi dans la noticeUniversité ou école supérieure
Division of Anatomy — Medical University of Vienna.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.