Aller au contenu principal
2025 conference-abstract

Abstract 4370823: Comparison of Cavotricuspid Isthmus Ablation Using Pulsed Field Versus Radiofrequency Energy in Patients Undergoing Pulmonary Vein Isolation with Pulsed Field Ablation

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background: Pulsed Field Ablation (PFA) has gained widespread adoption for pulmonary vein isolation (PVI) due to its tissue selectivity and safety profile. However, its role in cavotricuspid isthmus (CTI) ablation for typical atrial flutter is less defined. This study compares CTI ablation using PFA versus radiofrequency ablation (RFA) in patients undergoing PVI exclusively with PFA. Research Question: We hypothesized that in patients undergoing PFA-based PVI, CTI ablation using PFA would reduce procedure and fluoroscopy times without increasing complication or flutter recurrence rates compared to RFA. Methods: We retrospectively analyzed patients who underwent CTI ablation with either PFA or RFA alongside PFA PVI between 2024 – 2025 across all Mayo Clinic sites. Baseline characteristics, procedural parameters, acute success, and 12-month arrhythmia recurrence were compared between groups. All patients received standard follow-up, including ECGs and Holter monitoring. Results: A total of 350 patients were included (CTI PFA: n = 126; CTI RFA: n = 224). Patients in the PFA group were older (68.8 ± 8.5 vs. 65.7 ± 10.1 years; p <0.01) and had higher CHA2DS2-VASc scores (2.84 ± 1.57 vs. 2.45 ± 1.45; p = 0.02). Fluoroscopy (18.9 ± 9.1 vs. 25.2 ± 23.3 min; p < 0.01 ) and procedure times (172.6 ± 22.4 vs. 224.7 ± 74.2 min; p < 0.01) were significantly lower in the PFA group. Complication rates (8.7% vs. 4.9%; p = 0.15) and typical flutter recurrence (3.1% vs. 1.7%; p = 0.46) were similar between groups during a mean follow-up of 125 days. Conclusion: In patients undergoing PVI with PFA, CTI ablation using PFA is associated with significantly reduced procedure and fluoroscopy times compared to RFA, without increased complications or arrhythmia recurrence. These findings support the feasibility and efficiency of PFA for typical flutter ablation when performed during PFA-based AF procedures.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Abstract 4370823: Comparison of Cavotricuspid Isthmus Ablation Using Pulsed Field Versus Radiofrequency Energy in Patients Undergoing Pulmonary Vein Isolation with Pulsed Field Ablation
Date Crossref
04/11/2025
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Arrhythmias and TreatmentsAtrial Fibrillation Management and OutcomesCardiac electrophysiology and arrhythmias

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.