Abstract 4367166: A Multicenter Study of Detection of Pulmonary Hypertension Based on Point-of-Care 12- Lead ECG Data
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: Pulmonary hypertension (PH) is a life-threatening disease affecting up to 1% of the global population. Diagnosis can be challenging and is often delayed due to the need for advanced imaging and invasive procedures. The use of artificial intelligence applied to ECGs (ECG-AI) has been shown to detect subtle patterns in voltage-time data and may be a valuable tool for the early detection of PH. Hypothesis and Purpose: To evaluate the performance of a previously trained, ECG-AI algorithm to detect PH (ECG-AI PH) using real-world data (RWD) collected in a multicenter, validation study. A joint primary hypothesis required sensitivity (Sn), specificity (Sp), positive predictive value (PPV), and negative predictive value (NPV) to exceed the null values of 76%, 70%, 10% and 90%. Study Design and Methods: This retrospective validation study was conducted at 5 geographically diverse U.S. health systems. Adult subjects were eligible for inclusion if they had a 12-lead ECG paired with an echocardiogram (Echo) in which tricuspid regurgitation velocity (TRV) was recorded, following presentation with dyspnea. Patients were classified according to echocardiographic criteria as either PH (PH+, TRV >3.4 m/s) or controls (PH-, TRV ≤2.8 m/s) to simulate the real-world use of ECG-AI, where a positive result could lead to a follow-up Echo. The study database was locked before processing the digital ECGs with ECG-AI PH. Performance was also estimated in a subset of subjects that later had a right heart catheterization using mPAP ≥ 20mmHg as the definition of PH. Results: A total of 14281 subjects (53% female, 63% aged 50+ years) met the inclusion criteria, including 3019 PH+ cases and 11262 PH- controls (Figure). Sn and Sp were 84.0% (95% CI: 82.6%, 85.3%) and 71.7% (95% CI: 70.9%, 72.6%), respectively. The positive and negative predictive values were 18.9% (95% CI: 18.4%, 19.4%) and 98.3% (95% CI: 98.1%, 98.4%), respectively, at 7.3% prevalence. Each endpoint met pre-defined performance criteria. In the subset of 1683 subjects with a follow up RHC, performance remained robust (Sn 85% (1155/1358); Sp 46% (151/325)). Conclusion: While ECG-AI PH was first developed as an investigational tool to detect PH, continued development as software as a medical device for clinical use demonstrated that the algorithm retained strong performance to detect PH in diverse, non-overlapping clinical settings and patient populations.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Abstract 4367166: A Multicenter Study of Detection of Pulmonary Hypertension Based on Point-of-Care 12- Lead ECG Data
- Date Crossref
- 04/11/2025
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.