BACKGROUND: Load-independent indices of right ventricular (RV) dysfunction aid in the prognosis of patients with pulmonary hypertension (PH), but acquisition of these indices remains difficult. Simpler image-based tools could bring these metrics to everyday practice. OBJECTIVES: This study sought to develop a novel, artificial intelligence-based pipeline that estimates load-independent RV functional indices using a pressure-time waveform and stroke volume from clinical right-sided heart catheterization. METHODS: Clinical data and pressure-volume-time data were collected from 76 patients referred for right-sided heart catheterization for known or suspected PH from 3 centers. A computational pipeline was developed to determine the RV pressure-volume loop and extract load-independent RV indices using computer vision image processing and single-beat analysis. Agreement with gold standard single-beat analysis and prognostic value were evaluated. RESULTS: Strong concordance was observed between both methods for end-systolic elastance (Ees: R = 0.96; concordance correlation coefficient [CCC] = 0.58), effective arterial elastance (Ea: R = 0.97; CCC = 0.88), end-diastolic elastance (Eed: R = 0.87; CCC = 0.47), and Ees/Ea ratio (R = 0.93; CCC = 0.71) in both the validation and external cohorts. Prognostic analyses showed that calculated Ea (HR: 2.09; 95% CI: 1.04-4.20) and Ees/Ea (HR: 0.27; 95% CI: 0.08-0.87) were significant predictors of clinical outcomes. Cluster analysis using single-beat indices identified 2 RV subphenotypes with distinct hemodynamic features that were more predictive of poor outcomes than analysis using standard clinical features. CONCLUSIONS: Study investigators have developed a novel computational pipeline that digitizes and generates single-beat estimates of RV-pulmonary arterial coupling from an image of the RV pressure waveform and stroke volume. Its output correlates with single-beat methods and predicts clinical outcomes.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A Novel Computational Pipeline for Acquiring Pressure-Volume Hemodynamics of the Right Ventricle in Pulmonary Hypertension
Date Crossref
01/03/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Pulmonary Hypertension Research and TreatmentsCardiovascular Function and Risk FactorsHemodynamic Monitoring and Therapy

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.