Is sonographic measurement of head–perineum distance useful for predicting a need for instrument change in vacuum-assisted delivery?

0Citations signalées — pas une note de qualité
8Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: - Use of ultrasound before operative vaginal delivery (OVD), especially head-perineum distance (HPD) measurement, has shown promising results in the prediction of vacuum-assisted delivery failure. However, the studies were monocentric and there was variation in reported thresholds. OBJECTIVES: To assess HPD measurement as a predictor of the failure of vacuum-assisted delivery, requiring an instrument change. STUDY DESIGN: Multicenter, retrospective cohort study in three tertiary maternity hospitals in France, from January 2019 to December 2020. Analyses included all vacuum-assisted delivery attempts in singleton pregnancies of ≥ 34 weeks gestation and for which an ultrasound HPD measurement was available. Vacuum deliveries were classified as success or failure (i.e., leading to an instrument change). RESULTS: - Among 23,974 deliveries, vacuum delivery was performed in 2,432 cases (10.1 %) among which 1,197 (49.2 %) had HPD measurements. Instrument change occurred in 123 (10.3 %). The area under the curve for predicting the failure of a vaginal delivery with vacuum according to HPD measurement was 0.58, smaller in the success group (40.1 ± 12.6 mm vs 43.3 ± 10.9 mm, p <0.001). After multivariable analysis, gestational age and HPD were significantly associated with OVD failure (respectively, OR(95 %CI) 1.26 (1.05-1.51), p=0.015, 1.14 (1.04-1.25), p=0.004); whereas fetal head position did not reach the significance level (p=0.06). However more failure were observed in case of transverse position compared to anterior position (ORa = 2.10 (1.13 to 3.90)). CONCLUSION: - In our multicenter and retrospective study, HPD measurement has a low predictive value for the need for instrument change in vacuum-assisted OVD. It will be interesting to test mix models including maternal and sonographic parameters.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Is sonographic measurement of head–perineum distance useful for predicting a need for instrument change in vacuum-assisted delivery?
Date Crossref
01/01/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Maternal and Perinatal Health InterventionsPelvic floor disorders treatmentsAnesthesia and Pain Management

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.