Tricuspid Valve Transcatheter Edge-to-Edge Repair in Patients With Cardiac Implantable Electronic Devices
Résumé fourni par la source
BACKGROUND: Tricuspid valve transcatheter edge-to-edge repair (T-TEER) is increasingly used in patients with severe tricuspid regurgitation (TR) at high surgical risk. Long-term outcomes in those with transvalvular cardiac implantable electronic devices (CIEDs) remain insufficiently characterized. OBJECTIVES: The aim of this study was to evaluate procedural and clinical outcomes of T-TEER in patients with CIED leads in a real-world cohort. METHODS: Among 3,025 patients undergoing T-TEER at 26 centers (2016-2024), 851 (28.1%) had transvalvular CIED leads. Residual TR at discharge and follow-up and the composite of all-cause mortality or heart failure hospitalization at 2 years were assessed. CIED function was evaluated preprocedure and postprocedure. Propensity score matching (1:1) was conducted to compare outcomes between patients with and those without CIEDs. RESULTS: CIED function remained stable, and no lead revision was required. At discharge, TR ≤1+ and ≤2+ was achieved in 39.9% and 79.8%, respectively; at follow-up (median 269 days; Q1-Q3: 63-423 days), TR ≤1+ and ≤2+ persisted in 29.3% and 69.1%. In 385 matched pairs, residual TR, functional status, and 2-year heart failure hospitalization-free survival were comparable between patients with and those without CIEDs (67.1% [95% CI: 62.1%-72.5%] vs 73.6% [95% CI: 68.9%-78.6%]; P = 0.176). CIED presence showed a nonsignificant association with more adverse outcomes (HR: 1.31; 95% CI: 0.99-1.74; P = 0.063) but was not associated with residual TR >2+ (OR: 0.98; 95% CI: 0.70-1.38; P = 0.915). Achieving residual TR ≤2+ conferred significantly better survival irrespective of CIED presence (P < 0.001). CONCLUSIONS: T-TEER is safe and effective in selected patients with transvalvular CIED leads. Effective TR reduction remains prognostically relevant, even in this high-risk real-world population.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Tricuspid Valve Transcatheter Edge-to-Edge Repair in Patients With Cardiac Implantable Electronic Devices
- Date Crossref
- 01/12/2025
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.