Aller au contenu principal
Accès ouvert déclaré 2025 article

The effect of the ventilation rate on exposure to SARS-CoV-2 in a room with mixing ventilation

3Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Throughout the COVID-19 pandemic, guidance was to increase ventilation as a way to reduce the risk of transmission. While the benefits of ventilation, when it is used to supply fresh air or to remove virus laden air from a space, is indisputable, we show that in some circumstances it can also enhance the transport of virus from the infected to the uninfected. We used computational fluid dynamics to study exposure to SARS-CoV-2 from a person coughing, in a mechanically ventilated room with mixing ventilation, over short time periods. Models were run with three ventilation rates and two definitions for how the virus is distributed within different size droplets. These showed that up to 3 m from the person (the largest distance assessed in this work), the median exposure had a statistically significant increase as the ventilation rate was increased. For example, as the room air change rate was increased from 0.5 h −1 to 5 h −1 , the median exposure after 5 min increased by a factor of 7 or 134 depending on the model settings specified. The models showed that the negative impact of mixing ventilation on exposure (i.e. increased ventilation rate leading to increased exposure) reduced with time, which brings the predictions in line with the general guidance. Ventilation measures are therefore most likely to have the greatest impact on reducing transmission in spaces where people spend longer periods of time. • CFD was used to study exposure to SARS-CoV-2 in a mechanically ventilated room. • Two definitions were used to describe how virus was divided across exhaled droplets. • Close to a coughing person, exposure increased as ventilation rate increased. • Likelihood of ventilation increasing exposure reduced with time (5 vs 30 min). • Exposure is strongly dependent on how virus is divided across exhaled droplets.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
The effect of the ventilation rate on exposure to SARS-CoV-2 in a room with mixing ventilation
Date Crossref
01/12/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Infection Control and VentilationThermal Regulation in MedicineEvacuation and Crowd Dynamics

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.