Five-Year Clinical Outcomes and Durability of a Self-Expanding Transcatheter Heart Valve With Intra-Annular Leaflets
Rattachement africain : us, de, au, it. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: There is a paucity of data regarding the longer-term durability of transcatheter heart valves. This analysis aimed to describe the 5-year clinical outcomes and valve durability for patients treated with the Portico transcatheter heart valves across 3 studies harmonized in their prospective enrollment, inclusion/exclusion criteria, centralized independent core laboratory echocardiographic analysis, and independent clinical events committee adjudication. METHODS: Patient-level data from the PORTICO IDE randomized controlled trial, the PORTICO I postmarket study, and the PORTICO continued access protocol were pooled using a random-effects meta-analysis model. All 3 studies collected follow-up data at discharge, 30 days, and annually through 5 years. Adverse events and pooled echocardiographic data were assessed using Valve Academic Research Consortium-2 definitions. Durability definitions were adapted from Valve Academic Research Consortium-3 and European Association of Percutaneous Cardiovascular Interventions/European Society of Cardiology/European Association for Cardio-Thoracic Surgery consensus guidelines. RESULTS: , respectively, with paravalvular leak ≥moderate severity occurring in 1.9%. The 5-year bioprosthetic valve failure rate was 2.7%, including a 0.7% valve-related death rate and a 2.0% valve reintervention rate, but no patients with severe hemodynamic structural valve deterioration. Moderate hemodynamic structural valve deterioration occurred in 0.9% of the patients at 5 years. Hemodynamic performance and transcatheter heart valve durability remained stable irrespective of annular size. CONCLUSIONS: The use of the Portico transcatheter heart valve system in patients at high or extreme surgical risk demonstrated favorable clinical outcomes and hemodynamic performance with low transvalvular gradients and greater than mild paravalvular leak. Furthermore, bioprosthetic valve failure rates were low with no incidence of severe hemodynamic structural valve deterioration at 5 years, irrespective of annular size. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02000115 and NCT01802788.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Five-Year Clinical Outcomes and Durability of a Self-Expanding Transcatheter Heart Valve With Intra-Annular Leaflets
- Date Crossref
- 01/12/2025
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.