BACKGROUND: Transcatheter patent ductus arteriosus (PDA) closure can be challenging in cases of large PDA, complex anatomy, and small patient size. We aimed to assess the feasibility, efficacy and safety of the off-label use of the multifunctional occluder in transcatheter PDA closure. METHODS: A retrospective analysis was conducted on patients who underwent transcatheter PDA closure with the multifunctional occluder in 14 pediatric cardiology centers (5 countries) from 2018 to 2025. RESULTS: A total of 77 procedures were performed on 75 patients, including 5 adults (6.7%). Among the 70 children (93.3%; median age: 0.8 years [range, 0.1-10 years], median procedural weight: 6.9 kg [range, 2.1-32.0 kg]), 35 (50.0%) weighed ≤6 kg (median procedural weight: 4.0 kg [range, 2.1-5.9 kg]). The PDA was large, with a minimal ductal diameter of 3.8 mm (range, 1.5-7.0 mm), short in 54.5%, and unrestrictive with increased pulmonary artery pressures in 51.6% of patients. The morphology was predominantly conical (Krichenko type A: 51.9%), with window-type or complex morphologies representing 26.7% (Type B: 18.2%, Type D: 7.8%). Both arterial and venous femoral accesses were obtained in 87.0% cases, with deployment being antegrade in 77.9% and retrograde in 22.1%. Successful device deployment and release were achieved in 74 cases (96.1%). The rate of major adverse events was 5.2% including 1 early (1.3%) and 3 late complications (3.9%). No other adverse events were reported. CONCLUSIONS: The off-label use of the multifunctional occluder device is a promising option for transcatheter PDA closure, demonstrating safety and efficacy in this series.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Off‐Label Use of the Multifunctional Occluder for Transcatheter Patent Ductus Arteriosus Closure: An International Experience
- Date Crossref
- 21/10/2025
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.