Diagnostic performance of digital and traditional stethoscopes for detecting pneumonia-associated crackles in pediatric pneumonia patients
Rattachement africain : id. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background Advancements in healthcare technology have enabled the development of digital stethoscopes, enhancing auscultation in telemedicine practices. By remotely capturing and transmitting respiratory sounds, these devices improve physical examinations as well as the diagnosis and monitoring of respiratory diseases, particularly in remote or underserved areas. Objective To evaluate the sensitivity and specificity of a piezoelectric sensor-based digital stethoscope compared to a conventional stethoscope in detecting crackles associated with pediatric pneumonia. Methods This prospective comparative study involved 30 randomly selected pediatric pneumonia patients. Two pediatric pulmonologists independently assessed breath sounds in six lung areas using both digital and conventional stethoscopes. Findings were compared to evaluate the digital stethoscope’s sensitivity and specificity in detecting crackles, with the conventional stethoscope serving as the reference standard. Results The digital stethoscope demonstrated high sensitivity (>90%) and specificity (>90%) in detecting crackles, comparable to the conventional stethoscope. Examiner 1 achieved a sensitivity of 93.16%, a specificity of 97.10%, and an accuracy of 94.62%, while Examiner 2 achieved a sensitivity of 90.43%, a specificity of 91.55%, and an accuracy of 90.86%. The study highlights the potential of digital stethoscopes in telemedicine applications, particularly for pediatric respiratory assessments. Conclusion The digital stethoscope shows good diagnostic performance and may be a viable tool for remote auscultation. Its use may improve access to diagnostics in underserved areas or when in-person exams are difficult.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Diagnostic performance of digital and traditional stethoscopes for detecting pneumonia-associated crackles in pediatric pneumonia patients
- Date Crossref
- 22/09/2025
- Éditeur
- Paediatrica Indonesiana - Indonesian Pediatric Society
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
RSUD Prof. Dr. Saiful Anwar Malang pays non établi dans la noticeÉtablissement de santé
-
University of Brawijaya pays non établi dans la noticeUniversité ou école supérieure
-
Saiful Anwar Hospital Department of Pediatric pays non établi dans la noticeÉtablissement de santé
-
Faculty of Medicine Medical Study Program pays non établi dans la noticeUniversité ou école supérieure
RSUD Prof. Dr. Saiful Anwar Malang, University of Brawijaya et Department of Pediatric — Saiful Anwar Hospital, avec 1 autre affiliation.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.