Aller au contenu principal
Accès ouvert déclaré 2025 preprint

Low Arousal Threshold Endotype and CPAP Adherence: Insights from a Large, Diverse Clinical Cohort

3Citations signalées — pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

ABSTRACT Background A low respiratory arousal threshold (ArTH) has been linked to reduced continuous positive airway pressure (CPAP) adherence in obstructive sleep apnea (OSA) via a multi-trait model developed in the RICCADSA trial. Our objective was to validate the prior model in a large, real-world cohort and explore alternative linear and non-linear approaches for predicting CPAP adherence. Research Question Does a previously derived multi-trait model linking low ArTH to poor CPAP adherence remain valid in a diverse real-world population and do alternative linear or non-linear approaches offer improved predictive performance? Methods Adults with OSA from the SNOOzzzE-cohort who initiated CPAP within 1 year of in-lab polysomnography (2017–2019) were included. Pathophysiological traits (Vpassive, Vactive, loop gain, ArTH, ventilatory response to arousal) were estimated from polysomnography. Poor (vs good) adherence was defined as ≤2.48h/night at month 1 (1 st sample quartile). The prior model’s performance was evaluated via the area under the curve (AUC) and adherence comparisons. Secondary analyses tested a de novo linear regression and a latent profile analysis (LPA)–derived trait-cluster model. Results Among 744 participants (45% women, 47% non-White), median CPAP adherence was 4.8 h/night at 1 month. The prior model’s AUC was 0.51 (95%-CI 0.46–0.55), with no usage differences between predicted poor vs good adherers. A new linear model overfit in training (AUC=0.85) but failed in testing (AUC=0.55). LPA identified a “Low ArTH Driven” cluster with persistently lower adherence at months 2–3 (P<.05) and a “Low ArTH & High loop gain” cluster whose usage stabilized after month 1. Conclusions The prior model did not generalize to this diverse clinical cohort. LPA identified a “Low ArTH Driven” endotype with persistently low CPAP adherence, suggesting potential for targeted interventions pending external validation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Low Arousal Threshold Endotype and CPAP Adherence: Insights from a Large, Diverse Clinical Cohort
Date Crossref
19/10/2025
Éditeur
openRxiv
Type
posted-content

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Obstructive Sleep Apnea ResearchSleep and related disordersNeuroscience of respiration and sleep

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.