Screening for glaucoma with a novel eye movement perimetry technique based on continuous visual stimulus tracking

0Citations signalées — pas une note de qualité
4Institutions déclarées
3Pays d’affiliation déclarés

Résumé fourni par la source

Abstract Purpose Standard automated perimetry (SAP) is the gold standard for functional assessment in glaucoma. SAP can be too demanding for some groups of patients. Continuous visual stimulus tracking (SONDA: Standardized Oculomotor and Neurological Disorders Assessment) simplifies the perimetric task to following a moving stimulus on a screen. In this study we evaluated the screening performance of SONDA-based eye movement perimetry (SONDA-EMP) in glaucoma. To explore generalizability, we evaluated an experimental setup (SONDA-Eyelink) and a clinic-ready version (SONDA-Neon). Methods SONDA-Eyelink and SONDA-Neon measurements were performed in 100 cases with glaucoma (36, 36, and 28 with early, moderate, and severe glaucoma, respectively) and 100 age-similar controls. Participants monocularly tracked a moving stimulus (Goldmann size III) at 40% contrast (both setups) and 160% (SONDA-Eyelink). Eye movements were continuously recorded. Outcome was the agreement between gaze and stimulus position. We used previously collected glaucoma case-control data to build a continuous ‘glaucoma screening score’. This score was used for an ROC-analysis applied to the current, independently collected dataset. We predefined good screening performance as: at 95% specificity, a sensitivity of at least 50%, 90%, and 100% for early, moderate, and severe glaucoma, respectively. Results At 95% specificity, the sensitivity of SONDA-Eyelink was 58, 94, and 100% at 40% contrast and 56, 97, and 100% at 160% contrast for early, moderate, and severe glaucoma, respectively. Sensitivity was 53, 94, and 100% for SONDA-Neon. Conclusions SONDA-EMP is a novel, fast, and intuitive method to screen for visual function loss in glaucoma.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Screening for glaucoma with a novel eye movement perimetry technique based on continuous visual stimulus tracking
Date Crossref
17/10/2025
Éditeur
openRxiv
Type
posted-content

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Gaze Tracking and Assistive Technology

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.