Aller au contenu principal
Accès ouvert déclaré 2025 article

Performance of a Novel Computational Hyperemic Resistance Index Derived from Cardiac CT in Coronary Chronic Syndromes

1Citations signalées, ce qui n’est pas une note de qualité
6Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : fr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background/Objectives: Coronary artery disease (CAD) remains the leading global cause of mortality, underscoring the need for functional assessments that extend beyond anatomical evaluation. The Hyperemic Stenosis Resistance (HSR) index combines invasive pressure and flow parameters to assess stenosis severity but faces limitations due to methodological and standardization challenges. This study aimed to introduce and validate a novel non-invasive computational equivalent of HSR (cHSR), derived from coronary computed tomography angiography (CCTA), and to compare its diagnostic performance with fractional flow reserve derived from computational fluid dynamics (FFRCFD) and quantitative flow ratio (QFR). Methods: A retrospective analysis was conducted on 64 patients (106 coronary lesions) with suspected chronic coronary syndrome (CCS) who underwent both CCTA and invasive coronary angiography (ICA). Computational simulations incorporated patient-specific boundary conditions based on CCTA-derived left ventricular and aortic flow data. Diagnostic accuracy for predicting revascularization was compared among cHSR, FFRCFD, and QFR. Results: FFRCFD showed a strong correlation with invasive FFR (r = 0.87, p < 0.0001). The cHSR index achieved the highest diagnostic accuracy (96.2%) at an optimal cut-off of 0.75 mmHg/cm·s−1, outperforming both FFRCFD and QFR. No significant correlation was found between cHSR and shear stress parameters, including the Oscillatory Shear Index (OSI) and Time-Averaged Wall Shear Stress (TAWSS), indicating complex hemodynamic interactions beyond simple flow–pressure relationships. Conclusions: The computational hyperemic stenosis resistance (cHSR) index represents a promising non-invasive tool for the functional assessment of CAD, demonstrating superior diagnostic performance compared with existing imaging-based indices. Prospective multicenter studies with larger populations are warranted to confirm its clinical applicability and prognostic value in chronic coronary syndrome management.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Performance of a Novel Computational Hyperemic Resistance Index Derived from Cardiac CT in Coronary Chronic Syndromes
Date Crossref
15/10/2025
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Imaging and DiagnosticsCoronary Interventions and DiagnosticsAdvanced MRI Techniques and Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.