Aller au contenu principal
Accès ouvert déclaré 2025 article

Sizing procedure of low-enthalpy district heating and cooling heat pump plants: A case study of the Balearic Islands university campus

1Citations signalées — pas une note de qualité
2Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

• The methodology is used to size heat pump for low-enthalpy district heating and cooling networks. • It prevents oversizing compared to DIN EN 15450 standard. • Decentralized and centralized units are balanced to minimize ON/OFF cycling. • Thermal demand fluctuations and outdoor temperatures are integrated in the design. This study introduces a sizing procedure of low-enthalpy district heating and cooling heat pump plants to improve operational efficiency and prevent oversizing. The approach integrates thermal demand simulations with EnergyPlus™, a statistical analysis of thermal loads, and a Mixed-Integer Linear Programming optimization model. The methodology follows a two-step process: first, it decides the size and configuration of decentralized heat pump plants and then determines the capacity of the centralized plant among different predefined alternatives based on a statistical analysis of the thermal loads, considering existing units already installed in the buildings. Applied to the University of the Balearic Islands university campus, where a new district heating and cooling network will serve eight buildings, this methodology significantly reduces unmet thermal demand while ensuring that heat pumps operate within their compressor operational range for longer periods. Compared to traditional peak-load-based sizing, the proposed approach lowers installed capacity by 18.79% when considering the peak cooling demand of the entire network and 28.47% when analyzing each building individually. The findings underscore the importance of integrating demand fluctuations and outdoor temperature variations into system design. By balancing decentralized heat pump units with a centralized plant, this framework offers a scalable, energy-efficient solution for next-generation DHC networks that enhance sustainability while reducing the total installed capacity of the heat pumps.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Sizing procedure of low-enthalpy district heating and cooling heat pump plants: A case study of the Balearic Islands university campus
Date Crossref
01/01/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Integrated Energy Systems OptimizationBuilding Energy and Comfort OptimizationGeothermal Energy Systems and Applications

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.