Postoperative assessment of fracture reduction and osteosynthesis materials using photon-counting detector CT in maxillofacial trauma – a pilot study

8Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : ch, nl, de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

PURPOSE: To assess postoperative fracture reduction and visualization of titanium-based and bioresorbable osteosynthesis materials in maxillofacial trauma surgery using ultra-high-resolution photon-counting detector computed tomography (PCD-CT) compared with cone-beam computed tomography (CBCT). METHODS: Fractures were induced in six cadaveric pig mandibles at the angle, body, and parasymphysis and were stabilized using various titanium and bioresorbable plate systems. Specimens were scanned with CBCT and dose-matched PCD-CT in the ultra-high resolution mode, applying standard and low-dose protocols. Two observers assessed fracture reduction and implant delineation using a 5-point visual analog scale. Fracture gap and osteosynthesis materials were quantitatively measured and compared to ground-truth values. Descriptive statistics and inter-reader agreement (weighted κ) were calculated. RESULTS: PCD-CT enabled excellent assessment of fracture reduction and visualization of osteosynthesis materials, with perfect inter-observer agreement (Median = 5, IQR, 5-5; κ = 1.0, p < 0.001), whereas low-dose CBCT showed reduced image quality and lower reproducibility (Median = 4, IQR, 4-4; κ = 0.92; p < 0.001). Bioresorbable plates were not directly visible using either scanner, but the associated screw drill holes were reliably delineated. PCD-CT achieved the smallest measurement deviations of fracture gap and osteosynthesis materials compared with ground truth, and with superior reproducibility (κ = 0.74-0.84; ICC = 0.95-0.99; all p < 0.001), outperforming CBCT across most parameters. CONCLUSIONS: Ultra-high resolution PCD-CT combines superior visualization and precise measurements compared with CBCT even at low radiation dose. With further clinical validation, these findings highlight PCD-CT's strong potential for perioperative imaging in maxillofacial trauma, particularly benefiting younger patients who require repeated scans.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Postoperative assessment of fracture reduction and osteosynthesis materials using photon-counting detector CT in maxillofacial trauma – a pilot study
Date Crossref
11/10/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced X-ray and CT ImagingDental Radiography and ImagingFacial Trauma and Fracture Management

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.