Aller au contenu principal
Accès ouvert déclaré 2025 preprint

Novel CTC Detection Method in Patients with Pancreatic Cancer Using High-Resolution Image Scanning

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background/Objectives: Appropriate biomarkers are necessary for early diagnosis and multidisciplinary treatment of pancreatic ductal adenocarcinoma (PDAC). In recent years, the effectiveness of circulating tumor cells (CTCs) as biomarkers for various cancers has been reported; however, their detection rate in PDAC remains low, and sufficient evidence are not yet established. CTC detection methods with high reliability and performance are essential for clarifying the importance of CTCs in patients with PDAC. Methods: A total of 5 mL peripheral blood samples were collected from 38 patients newly diagnosed with PDAC and 17 healthy controls. Negative enriched cells were immunoflu-orescently stained with EpCAM-phycoerythrin and cell surface vimentin-fluorescein isothiocyanate(CSV). Images were automatically captured using an all-in-one fluorescence microscope. Cellular regions were detected from the captured images and the average lu-minance of the cellular regions was calculated. A total of 9086 and 1071 cell images were obtained from patients with PDAC and healthy controls, respectively. Results: In the Ep-CAM assay, a threshold that included 95% of healthy individuals was optimal for distin-guishing patients with PDAC from healthy controls, with a sensitivity, specificity, and AUC of 0.74, 0.76, and 0.84, respectively. At this threshold, the CTC-positivity rate in pa-tients with PDAC was 76.3%. Conversely, the CSV assay failed to demonstrate a valid threshold to distinguish patients with PDAC from healthy controls. No significant differ-ences were found between CTC and clinicopathological features among patients with PDAC. Conclusions: This method using high resolution image scanning has the potential to identify CTCs with greater objectivity by quantifying cell luminance values.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Novel CTC Detection Method in Patients with Pancreatic Cancer Using High-Resolution Image Scanning
Date Crossref
06/10/2025
Éditeur
MDPI AG
Type
posted-content

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Radiomics and Machine Learning in Medical ImagingPancreatic and Hepatic Oncology Research

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.