Aller au contenu principal
Accès ouvert déclaré 2025 article

Utility of 18 F-Flurpiridaz PET Relative Flow Reserve in Differentiating Obstructive From Nonobstructive Coronary Artery Disease

7Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : us, es. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Absolute quantification of myocardial blood flow (MBF) on positron emission tomography perfusion imaging improves the identification of coronary artery disease (CAD). However, distinguishing MBF impairment due to obstructive CAD from nonobstructive CAD remains challenging. We aimed to evaluate the incremental diagnostic value of positron emission tomography derived relative flow reserve (RFR) in the diagnosis of obstructive CAD. METHODS: This is a post hoc analysis of the multicenter phase III trial of 18 F-flurpiridaz positron emission tomography. Patients with available MBF quantification were included. Reduced stress MBF (sMBF) was defined as sMBF below the median (2.2 mL/min per gram). Obstructive CAD on quantitative invasive coronary angiography was defined as ≥70% stenosis. RFR was calculated as a ratio of the minimal segment sMBF over the highest reference vascular territory sMBF. RFR performance for predicting obstructive CAD was evaluated through receiver operating characteristic analysis and the net reclassification index of multivariable regression models. RESULTS: The study included 231 patients (71% male; 56% with established CAD) drawn from the original cohort of 755 trial participants. No patients had 3-vessel CAD. In a per-vessel-based analysis, 82% of vessels with reduced sMBF had no obstructive CAD on invasive coronary angiography. RFR was significantly lower for vessels with obstructive CAD (0.55 versus 0.80; P <0.0001). In vessels with reduced sMBF, RFR was independently associated with obstructive CAD even after accounting for stress total perfusion deficit and myocardial flow reserve (odds ratio, 3.08 [95% CI, 1.49–6.38]; P =0.002). Although the addition of RFR did not significantly improve discrimination (area under the curve, 0.806 versus 0.822; P =0.11), it significantly improved reclassification of vessels with and without obstructive CAD (net reclassification index, 0.93; obstructive CAD net reclassification index, 0.44; nonobstructive CAD net reclassification index, 0.49; P <0.0001). CONCLUSIONS: RFR provides complementary diagnostic information beyond existing positron emission tomography parameters and may help refine the diagnosis of obstructive CAD in patients with reduced flows. REGISTRATION: URL: https://clinicaltrials.gov ; Unique identifier: NCT01347710.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
Utility of <sup>18</sup> F-Flurpiridaz PET Relative Flow Reserve in Differentiating Obstructive From Nonobstructive Coronary Artery Disease
Date Crossref
01/11/2025
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Imaging and DiagnosticsMedical Imaging Techniques and ApplicationsCardiovascular Function and Risk Factors

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.