Helium Range Viability for Online Range Probing in Mixed Carbon-Helium Beams

0Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

Background: Recently, mixed carbon-helium beams were proposed for range verification in carbon ion therapy: Helium, with three times the range of carbon, serves as an on-line range probe, and is mixed into a therapeutic carbon beam. Purpose: Treatment monitoring is of special interest for lung cancer therapy, however the helium range might not always be sufficient to exit the patient distally. Therefore mixed beam use cases of several patient sites are considered. Methods: An extension to the open-source planning toolkit, matRad allows for calculation and optimization of mixed beam treatment plans. The use of the mixed beam method in 15 patients with lung cancer, as well as in a prostate and liver case, for various potential beam configurations was investigated. Planning strategies to optimize the residual helium range considering the sensitive energy range of the imaging detector were developed. A strategy involves adding helium to energies whose range is sufficient. Another one is to use range shifters to increase the helium energy and thus range. Results: In most patient cases, the residual helium range of at least one spot is too low. All investigated planning strategies can be used to ensure a high enough helium range while still keeping a low helium dose and a satisfactory total mixed carbon-helium beam dose. The use of range shifters allows for the detection of more spots. Conclusion: The mixed beam method shows promising results for online motioning. The use of range shifters ensures a high enough helium range and more detectable spots, allowing for a wider-spread application.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les sujets associés

Particle accelerators and beam dynamicsPlasma Diagnostics and ApplicationsParticle Accelerators and Free-Electron Lasers

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.