Real‐Time Deep‐Learning Image Reconstruction and Instrument Tracking in MR ‐Guided Biopsies
Résumé fourni par la source
BACKGROUND: Transrectal in-bore MR-guided biopsy (MRGB) is accurate but time-consuming, limiting clinical throughput. Faster imaging could improve workflow and enable real-time instrument tracking. Existing acceleration methods often use simulated data and lack validation in clinical settings. PURPOSE: To accelerate MRGB by using deep learning for undersampled image reconstruction and instrument tracking, trained on multi-slice MR DICOM images and evaluated on raw k-space acquisitions. STUDY TYPE: Prospective feasibility study. POPULATION: Briefly, 1289 male patients (aged 44-87, median age 68) for model training, 8 male patients (aged 59-78, median age 65) for prospective feasibility testing. FIELD STRENGTH/SEQUENCE: 2D Cartesian balanced steady-state free precession, 3 T. ASSESSMENT: Segmentation and reconstruction models were trained on 8464 MRGB confirmation scans containing a biopsy needle guide instrument and evaluated on 10 prospectively acquired dynamic k-space samples. Needle guide tracking accuracy was assessed using instrument tip prediction (ITP) error, computed per frame as the Euclidean distance from reference positions defined via pre- and post-movement scans. Feasibility was measured by the proportion of frames with < 5 mm error. Additional experiments tested model robustness under increasing undersampling rates. STATISTICAL TESTS: In a segmentation validation experiment, a one-sample t-test tested if the mean ITP error was below 5 mm. Statistical significance was defined as p < 0.05. In the tracking experiments, the mean, standard deviation, and Wilson 95% CI of the ITP success rate were computed per sample, across undersampling levels. RESULTS: ITP was first evaluated independently on 201 fully sampled scans, yielding an ITP error of 1.55 ± 1.01 mm (95% CI: 1.41-1.69). Tracking performance was assessed across increasing undersampling factors, achieving high ITP success rates from 97.5% ± 5.8% (68.8%-99.9%) at 8× up to 92.5% ± 10.3% (62.5%-98.9%) at 16× undersampling. Performance declined at 18×, dropping to 74.6% ± 33.6% (43.8%-91.7%). DATA CONCLUSION: Results confirm stable needle guide tip prediction accuracy and support the robustness of the reconstruction model for tracking at high undersampling. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 2.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.
- Titre Crossref
- Real‐Time Deep‐Learning Image Reconstruction and Instrument Tracking in <scp>MR</scp> ‐Guided Biopsies
- Date Crossref
- 01/10/2025
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.