Multi-dimensional evaluation and synergistic optimization for double-circuit distribution lines under transient events

4Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : hk, cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Lightning-induced Overvoltage (LIOV) represents a critical factor impacting the stability and reliability of equipment in distribution systems. Despite its significance, existing studies lack systematic analysis of LIOV characteristics and protection strategies in 10 kV double-circuit distribution lines when adjacent circuits are struck by direct lightning stroke. This study aims to quantify the effects of Surge Arrester (SA) deployment density, Shielding Wire (SW) grounding intervals, and grounding resistance on LIOV, and to propose optimal protection schemes balancing performance and cost. A hybrid simulation model, based on the Partial Element Equivalent Circuit (PEEC) method with the Variable Time Step (VTS) strategy, was developed to simulate LIOV responses in a double-circuit distribution system. Lightning current waveforms were modeled by the Heidler function, and SAs were represented by IEEE-recommended frequency-dependent circuits. Results show that SA deployment with one-pole intervals enhances the one-phase flashover lightning withstand level from 1.7 kA to 3.9 kA. This performance is better than that of SW alone where three-pole grounded SW achieve a one-phase flashover lightning withstand level of 38.7 kA. Combining one-pole SA intervals with one-pole grounded SW reduces flashover rates by 30% while maintaining economic feasibility. The findings provide valuable theoretical support for practical lightning protection designs in double-circuit distribution systems. • Comprehensive investigation of lightning-induced overvoltage on double-circuit distribution systems, focusing on overvoltage when adjacent circuits are directly struck by lightning. • Systematic revelation of synergistic regulation mechanisms across configurations, achieving breakthroughs in multi-dimensional protection optimization. • Identification of optimal lightning protection strategies balancing technical performance and economy for double-circuit distribution systems.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Multi-dimensional evaluation and synergistic optimization for double-circuit distribution lines under transient events
Date Crossref
01/11/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Lightning and Electromagnetic PhenomenaElectromagnetic Compatibility and Noise SuppressionThermal Analysis in Power Transmission

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.