Outcomes of transcatheter patent ductus arteriosus closure in infants weighing 2 to 6 kg
Rattachement africain : fr, in, gb, be, ch, us, se, lb, pl, my, Égypte, ar, il, no, br, it, mq. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
INTRODUCTION AND OBJECTIVES: Transcatheter patent ductus arteriosus (PDA) closure is safe in<2-kg infants and in≥6-kg patients, but major safety concerns remain when applied to the intermediate weight range. We aimed to assess outcomes of transcatheter PDA closure in 2- to 6-kg infants. METHODS: An international, multicenter, retrospective cohort study was conducted in 31 tertiary hospitals in 17 countries between 2000 and 2023, investigating all infants who underwent attempted transcatheter PDA closure with a procedural weight of 2-to-6kg. RESULTS: Attempted transcatheter PDA closure was performed in 1231 infants (median [Q1-Q3] weight, 4747 [3700-5300] g; median age, 132 [83-194] days; ex-preterm, n=581 [56.8%]) with a 95.0% success rate. A composite outcome of procedural failure or major adverse events was observed in 173 (14%) patients, including device embolization in 64 (3.7%), device-induced left pulmonary artery stenosis in 47 (2.7%), and procedural death in 2 (0.2%). Logistic regression model analysis identified a 2- to 3.9-kg procedural weight, increased pulmonary artery pressure, and window-type or tubular ductal morphologies as independent predictors of the composite outcome. Based on propensity score matching analysis, 2- to 3.9-kg infants had a risk ratio of 2.19 (95%CI, 1.25-3.83) for experiencing the composite outcome, compared with 4- to 5.9-kg infants. CONCLUSIONS: Transcatheter PDA closure in 2- to 6-kg infants was feasible in most patients. Procedural failure or major adverse events occurred in 14% and several independent risk factors were identified, including the 2- to 3.9-kg weight range identified as a higher-risk subgroup. These findings may improve risk stratification and the decision-making process.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Outcomes of transcatheter patent ductus arteriosus closure in infants weighing 2 to 6 kg
- Date Crossref
- 01/04/2026
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.