Shear-Wave Anisotropy of the Vastus Lateralis During Low-Level Isometric Contraction Measured with Ultrasound Time-Harmonic Elastography

1Citations signalées — pas une note de qualité
7Institutions déclarées
3Pays d’affiliation déclarés

Résumé fourni par la source

Abstract Purpose Skeletal muscle is commonly modeled as a transverse isotropic medium, however, the behavior of its anisotropy under active loading remains insufficiently characterized. In this study we used ultrasound time-harmonic elastography (THE) to quantify direction-dependent shear-wave speed (SWS) in the vastus lateralis (VL) muscle at rest and during low isometric contraction intensities. Methods Twenty-six healthy adults (15 men, 11 women; 25.0 ± 4.1 y) under-went multi-frequency THE (60–80 Hz). The transducer was aligned parallel (longitudinal) and perpendicular (transverse) to VL fascicles, and measurements were acquired at rest and at 15% and 30% of maximal voluntary contraction (MVC). The anisotropy index (AI) was defined as AI = SW S ∥ /SW S ⊥ . Orientation and contraction effects were tested with repeated-measures analyses. Results At rest, longitudinal SWS exceeded transverse SWS ( 2.5 ± 0.2 vs. 1.4 ± 0.1 m/s; paired t-test p < 0.01 ). With contraction, SWS increased to 3.2 ± 0.2 and 3.8 ± 0.3 m/s (15%, 30% MVC) along fibers, and to 1.6 ± 0.1 and 1.8 ± 0.1 m/s across fibers (all p < 0.01 ). A two-factor repeated-measures ANOVA on SWS showed main effects of orientation and contraction and a significant interaction (all p < 0.01 ). AI increased from 1.7 ± 0.1 at rest to 2.0 ± 0.1 at 15% and 2.1 ± 0.1 at 30% MVC ( p < 0.01 ). No sex- or BMI-related effects were detected. Conclusion VL exhibited marked shear-wave anisotropy at rest that increased with low-level contraction intensities, indicating disproportionate stiffening along the fiber direction. THE provides a rapid, cost-effective, orientation-sensitive readout of muscle mechanics that may support studies of neuromuscular function and pathology.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Shear-Wave Anisotropy of the Vastus Lateralis During Low-Level Isometric Contraction Measured with Ultrasound Time-Harmonic Elastography
Date Crossref
19/08/2026
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Ultrasonics and Acoustic Wave PropagationUltrasound Imaging and ElastographyElasticity and Material Modeling

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.