Peroneus Longus Autograft Harvest: Patient-Reported Donor-Ankle Morbidity at 1 Year

2Citations signalées — pas une note de qualité
4Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: The peroneus longus (PL) tendon is increasingly used as an autograft for ligament and tendon reconstructions, particularly in populations where hamstring graft dimensions may be insufficient. However, donor-site ankle function and patient-reported outcomes measures (PROMs) after PL harvest remain underreported. This study aimed to evaluate changes in PROMs and range of motion (ROM) at the donor-site ankle 1 year after PL autograft harvest and the proportion exceeding minimal clinically important difference (MCID) thresholds. METHODS: Patients who underwent PL autograft harvest from January 2021 through April 2023 were retrospectively enrolled. PROMs-including the Single Assessment Numeric Evaluation (SANE), American Orthopaedic Foot & Ankle Society (AOFAS) score, Foot and Ankle Outcome Score (FAOS), and Cumberland Ankle Instability Tool (CAIT) score-were assessed preoperatively and at 1-year follow-up on the operated ankle. Ankle ROM was also measured. Donor-site morbidity was evaluated using MCID thresholds. RESULTS: < .05), with postoperative scores of SANE (92.3 ± 27.3), AOFAS (96.7 ± 10.7), FAOS (97.0 ± 23), and CAIT (27.4 ± 19.4). MCID thresholds were exceeded in 51.4% (SANE), 31.4% (AOFAS), 34.2% (FAOS), and 5.7% (CAIT) of patients. Two patients experienced transient sural nerve hypoesthesia, which resolved without long-term deficit. CONCLUSION: PL tendon harvest was associated with preserved ankle ROM at 1 year but demonstrated statistically significant declines in PROMs compared with preoperative baselines. A subset of patients exceeded MCID thresholds, indicating clinically meaningful donor-site morbidity in some cases. These findings underscore the importance of informed graft selection and highlight the need for further long-term evaluation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Peroneus Longus Autograft Harvest: Patient-Reported Donor-Ankle Morbidity at 1 Year
Date Crossref
30/09/2025
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Foot and Ankle SurgeryKnee injuries and reconstruction techniquesOrthopedic Surgery and Rehabilitation

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.