Aller au contenu principal
Accès ouvert déclaré 2025 article

Diagnostic accuracy of computer-aided detection (CAD)-derived solid component proportion and mean CT attenuation for predicting invasiveness in pulmonary part-solid nodules: a retrospective study

0Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : cn, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background: Accurate preoperative identification of invasiveness in pulmonary part-solid nodules (PSNs) is critical to guide extent of resection and operative timing, yet reliable, automated imaging markers are limited. This study aimed to evaluate the predictive value of volumetric proportion and mean computed tomography (CT) value of solid components for the invasiveness of pulmonary PSNs using computer-aided detection (CAD). Methods: (AIS), minimally invasive adenocarcinoma (MIA), or invasive adenocarcinoma (IA). The proportion of solid components at CT values of -300 Hounsfield units (HU) and -400 HU and the mean CT values of the solid components were automatically computed. The diagnostic accuracy was evaluated with the area under the receiver operating characteristic curve (AUC). The tumor size was stratified, and the optimal predictive indicators within each stratum were evaluated. Results: Among 313 patients (324 PSNs; median age 58 years), 4 AAH, 88 AIS, 69 MIA, and 163 IA were identified. The mean CT value of the solid component had an AUC of 0.795 (threshold -144.5 HU), with sensitivity 0.799, and specificity 0.696. Tumor size had an AUC of 0.784 (threshold 1.65 cm, sensitivity 0.595, specificity 0.826), and solid component size had an AUC of 0.759 (threshold 0.95 cm, sensitivity 0.804, specificity 0.509). Analysis of solid component proportion demonstrated AUCs of 0.795 and 0.783 at -300 and -400 HU, respectively, with corresponding optimal thresholds of 16.2% (sensitivity 0.706, specificity 0.814) and 31.3% (sensitivity 0.687, specificity 0.807). In the stratified analysis, the mean CT value and solid component proportion showed high AUCs in all tumor size strata. Conclusions: CAD-derived volumetric solid proportion and mean CT attenuation show promise for predicting PSN invasiveness in this single-center retrospective cohort; prospective multicenter validation with standardized protocols is warranted.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Diagnostic accuracy of computer-aided detection (CAD)-derived solid component proportion and mean CT attenuation for predicting invasiveness in pulmonary part-solid nodules: a retrospective study
Date Crossref
01/09/2025
Éditeur
AME Publishing Company
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Lung Cancer Diagnosis and TreatmentRadiomics and Machine Learning in Medical ImagingAdvanced Radiotherapy Techniques

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.