Association of Tonotopic Mismatch and Cochlear Implant Use on Outcomes for Adults With Unilateral Hearing Loss
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
ABSTRACT Objective Review whether tonotopic mismatch and device use are associated with speech recognition for adult cochlear implant (CI) users with unilateral hearing loss (UHL). Methods Performance with the CI alone (CNC word scores) and in the CI plus the normal hearing (NH) ear condition (CI + NH; BKB‐SIN scores) at 6 months post‐activation was reviewed. For BKB‐SIN, the target was presented from the front and the masker was presented toward the NH ear. Mismatch for the most apical electrode contact was determined using imaging and the filter frequencies of each patient's familiar map. Device use was obtained from datalogging reports. Results For the 32 CI recipients, mismatch ranged from −27 to 21 semitones (mean: −8; SD: 10). Mismatch was not significantly associated with CNC scores ( r (32) = −0.25, p = 0.083) but was with BKB‐SIN scores ( r (26) = 0.38, p = 0.030). Device use ranged from 1 to 14 h (mean: 7; SD: 5). Device use was significantly associated with CNC ( r (24) = 0.56, p = 0.002) and BKB‐SIN ( r (21) = −0.49, p = 0.012) scores. The relationship between mismatch and device use was not significant ( r (24) = −0.11, p = 0.308). Conclusion CI users with UHL experienced better speech recognition when tonotopic mismatches were minimal or not present, and when they listened to their CI for multiple hours a day. These data suggest that CI users with UHL may experience their best performance with consistent device use and when listening to maps with minimal or no tonotopic mismatch. The lack of a significant association between mismatch and device use suggests other variables may be influencing the consistency of device use. Level of Evidence 4.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Association of Tonotopic Mismatch and Cochlear Implant Use on Outcomes for Adults With Unilateral Hearing Loss
- Date Crossref
- 29/09/2025
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.