Aller au contenu principal
Accès ouvert déclaré 2025 article

Electromagnetic energy calibration of the SoLid detector with horizontal muons

0Citations signalées, ce qui n’est pas une note de qualité
28Institutions déclarées
7Pays d’affiliation déclarés

Rattachement africain : be, fr, gb, au, de, ch, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract SoLid is a neutrino experiment at very-short baseline searching for active-to-sterile oscillations of reactor antineutrinos. The detection principle is based on the pairing of two types of solid scintillators: polyvinyl toluene and 6Li:ZnS(Ag), which is a new technology used in this field of Physics. In addition to good neutron-gamma discrimination, this setup allows the detector to be highly segmented; the basic detection unit is a 5 cm cube. High segmentation provides numerous advantages including precise localisation of the Inverse Beta Decay (IBD) products, the derivation of an antineutrino energy estimator based on the isolated positron energy, and a powerful background reduction tool that relies on the topological signature of the signal. Finally, the system is read out by a network of wavelength-shifting fibres coupled to photosensors. A relative electromagnetic calibration is performed with horizontal cosmic muons. This source poses the simplest calibration problem in which a single detection unit is involved. In addition, large muon energy deposits allow us to perform a calibration at the most detailed level (i.e. per fibre) and to accurately define the fraction of energy escaping to neighbouring detection cells. A statistical precision at the sub-percent level is reached. The paper also discusses two methods to calibrate the absolute energy scale and presents their implementation and results. The first method relies on horizontal muons, though the precision is limited to around 10% because of the uncertainty in the energy distribution of such muons. A novel, alternative method based on the radioactive americium-beryllium source is proposed. It takes advantage of the electron-positron pair-production process and provides a calibration point at 3.4 MeV (i.e. in the core of the IBD positron spectrum). The paper is concluded with various cross-check including a determination of the energy spectrum of the standard cosmogenic background candle: 12B.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Electromagnetic energy calibration of the SoLid detector with horizontal muons
Date Crossref
01/10/2025
Éditeur
IOP Publishing
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Particle physics theoretical and experimental studiesParticle Detector Development and PerformanceNeutrino Physics Research

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.