Analysis and Optimization of Dynamic Characteristics of Primary Frequency Regulation Under Deep Peak Shaving Conditions for Industrial Steam Extraction Heating Thermal Power Units

2Citations signalées — pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

This study investigates the primary frequency regulation dynamic characteristics of industrial steam extraction turbine units under deep peak regulation conditions. A high-fidelity integrated dynamic model was established, incorporating the governor system, steam turbine with extraction modules, and interconnected pipeline dynamics. Through comparative simulations and experimental validation, the model demonstrates high accuracy in replicating real-unit responses to frequency disturbances. For the power grid system in this study, the frequency disturbance mainly comes from three aspects: first, the power imbalance formed by the random mutation of the load side and the intermittence of new energy power generation; second, transformation of the energy structure directly reduces the available frequency modulation resources; third, the system-equivalent inertia collapse effect caused by the integration of high permeability new energy; the rotational inertia provided by the traditional synchronous unit is significantly reduced. In the cogeneration unit and its control system in Guangxi involved in this article, key findings reveal that increased peak regulation depth (30~50% rated power) exacerbates nonlinear fluctuations. This is due to boiler combustion stability thresholds and steam pressure variations. Key parameters—dead band, power limit, and droop coefficient—have coupled effects on performance. Specifically, too much dead band (>0.10 Hz) reduces sensitivity; likewise, too high a power limit (>4.44%) leads to overshoot and slow recovery. The robustness of parameter configurations is further validated under source-load random-intermittent coupling disturbances, highlighting enhanced anti-interference capability. By constructing a coordinated control model of primary frequency modulation, the regulation strategy of boiler and steam turbine linkage is studied, and the optimization interval of frequency modulation dead zone, adjustment coefficient, and frequency modulation limit parameters are quantified. Based on the sensitivity theory, the dynamic influence mechanism of the key control parameters in the main module is analyzed, and the degree of influence of each parameter on the frequency modulation performance is clarified. This research provides theoretical guidance for optimizing frequency regulation strategies in coal-fired units integrated with renewable energy systems.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Analysis and Optimization of Dynamic Characteristics of Primary Frequency Regulation Under Deep Peak Shaving Conditions for Industrial Steam Extraction Heating Thermal Power Units
Date Crossref
26/09/2025
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Advanced Power Generation TechnologiesGeomechanics and Mining EngineeringAdvanced Algorithms and Applications

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.