Aller au contenu principal
Accès ouvert déclaré 2025 article

Artificial Intelligence-Led Whole Coronary Artery OCT Analysis; Validation and Identification of Drug Efficacy and Higher-Risk Plaques

7Citations signalées, ce qui n’est pas une note de qualité
9Institutions déclarées
5Pays d’affiliation déclarés

Rattachement africain : gb, au, us, ch, it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Intracoronary optical coherence tomography (OCT) can identify changes following drug/device treatment and high-risk plaques, but analysis requires expert clinician or core laboratory interpretation, while artifacts and limited sampling markedly impair reproducibility. Assistive technologies such as artificial intelligence-based analysis may therefore aid both detailed OCT interpretation and patient management. We determined if artificial intelligence-based OCT analysis (AutoOCT) can rapidly process, optimize, and analyze OCT images, and identify plaque composition changes that predict drug success/failure and high-risk plaques. METHODS: AutoOCT deep learning artificial intelligence modules were designed to correct segmentation errors from poor-quality or artifact-containing OCT images, identify tissue/plaque composition, classify plaque types, measure multiple parameters including lumen area, lipid and calcium arcs, and fibrous cap thickness, and output segmented images and clinically useful parameters. Model development used 36 212 frames (127 whole pullbacks, 106 patients). Internal validation of tissue and plaque classification and measurements used ex vivo OCT pullbacks from autopsy arteries, while external validation for plaque stabilization and identifying high-risk plaques used core laboratory analysis of IBIS-4 (Integrated Biomarkers and Imaging Study-4) high-intensity statin (83 patients) and CLIMA (Relationship Between Coronary Plaque Morphology of Left Anterior Descending Artery and Long-Term Clinical Outcome Study; 62 patients) studies, respectively. RESULTS: AutoOCT recovered images containing common artifacts with measurements and tissue and plaque classification accuracy of 83% versus histology, equivalent to expert clinician readers. AutoOCT replicated core laboratory plaque composition changes after high-intensity statin, including reduced lesion lipid arc (13.3° versus 12.5°) and increased minimum fibrous cap thickness (18.9 µm versus 24.4 µm). AutoOCT also identified high-risk plaque features leading to patient events including minimal lumen area <3.5 mm 2 , Lipid arc >180°, and fibrous cap thickness <75 µm, similar to the CLIMA core laboratory. CONCLUSIONS: AutoOCT-based analysis of whole coronary artery OCT identifies tissue and plaque types and measures features correlating with plaque stabilization and high-risk plaques. Artificial intelligence-based OCT analysis may augment clinician or core laboratory analysis of intracoronary OCT images for trials of drug/device efficacy and identifying high-risk lesions.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Artificial Intelligence-Led Whole Coronary Artery OCT Analysis; Validation and Identification of Drug Efficacy and Higher-Risk Plaques
Date Crossref
01/11/2025
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Coronary Interventions and DiagnosticsOptical Coherence Tomography ApplicationsCardiac Imaging and Diagnostics

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.