Comparative analysis of cardiac function before LVAD implantation in patients with and without early, acute right heart failure: insights from cardiac magnetic resonance

1Citations signalées — pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Background Early acute right heart failure (eaRHF) during left ventricular assist device (LVAD) implantation significantly impacts patient survival and complicates perioperative management. Although numerous clinical, echocardiographic, and hemodynamic risk factors have been identified, accurately predicting eaRHF remains challenging. Cardiac magnetic resonance (CMR) provides a precise, non-invasive evaluation of cardiac structure and function and may enhance risk stratification eaRHF. This study aims to assess the predictive value of preoperative CMR-derived parameters, comparing their utility to established echocardiographic and right heart catheterization (RHC) markers for identifying eaRHF. Methods This retrospective analysis was conducted on 55 patients who received CMR before LVAD implantation at our center between 2018 and 2024. Of these 55 patients, 40 had image quality sufficient for offline analysis. Patients receiving a temporary right ventricular assist device (tRVAD) intraoperatively were defined as having eaRHF. Receiver Operating Characteristic (ROC) analysis was used to evaluate the predictive capability of CMR, echocardiographic, and RHC parameters. Results Ten patients (25%) developed eaRHF. Preoperative bilirubin levels were significantly higher in the eaRHF group (1.6 mg/dl vs. 1.1 mg/dl, p = 0.010). Echocardiographic Tricuspid Annular Plane Systolic Excursion (TAPSE) tended to be lower in eaRHF patients (12 mm vs. 18 mm, p = 0.080). RHC parameters, specifically right ventricular stroke work index (RV-SWI; p < 0.001), cardiac output (CO; p = 0.003), and cardiac index (CI; p = 0.004), were significantly lower in eaRHF patients. CMR showed significantly higher RV end-diastolic volumes (RV-EDV, 288.4 ml vs. 216.7 ml, p = 0.046) and indexed RV-EDV (RV-EDVi, 135.4 ml/m2 vs. 104.7 ml/m2, p = 0.033) in the eaRHF group. ROC analysis identified CO (AUC = 0.90, sensitivity = 100%, specificity = 72%, p < 0.001), CI (AUC = 0.88, sensitivity = 83%, specificity = 83%, p < 0.001), and RV-SWI (AUC = 0.86, sensitivity = 83%, specificity = 86%, p < 0.001) as strong predictors. Moderate predictive values were observed for RV-EDVi (AUC = 0.73, p = 0.040) and RV global radial strain (RV-GRS; AUC = 0.70, p = 0.044). Conclusion Hemodynamic parameters from RHC demonstrated the strongest predictive capability for eaRHF. However, selected CMR-derived parameters, especially indexed RV-EDV and RV GRS, offer moderate predictive value and may serve as adjunctive tools in preoperative risk stratification for LVAD candidates.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comparative analysis of cardiac function before LVAD implantation in patients with and without early, acute right heart failure: insights from cardiac magnetic resonance
Date Crossref
24/09/2025
Éditeur
Frontiers Media SA
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Mechanical Circulatory Support DevicesCongenital Heart Disease StudiesTransplantation: Methods and Outcomes

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.