Aller au contenu principal
2025 article

Including AI in diffusion-weighted breast MRI has potential to increase reader confidence and reduce workload

0Citations signalées — pas une note de qualité
11Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

OBJECTIVES: Breast diffusion-weighted imaging (DWI) has shown potential as a standalone imaging technique for certain indications, eg, supplemental screening of women with dense breasts. This study evaluates an artificial intelligence (AI)-powered computer-aided diagnosis (CAD) system for clinical interpretation and workload reduction in breast DWI. MATERIALS AND METHODS: This retrospective IRB-approved study included: n = 824 examinations for model development (2017-2020) and n = 235 for evaluation (01/2021-06/2021). Readings were performed by three readers using either the AI-CAD or manual readings. BI-RADS-like (Breast Imaging Reporting and Data System) classification was based on DWI. Histopathology served as ground truth. The model was nnDetection-based, trained using 5-fold cross-validation and ensembling. Statistical significance was determined using McNemar's test. Inter-rater agreement was calculated using Cohen's kappa. Model performance was calculated using the area under the receiver operating curve (AUC). RESULTS: The AI-augmented approach significantly reduced BI-RADS-like 3 calls in breast DWI by 29% (P =.019) and increased interrater agreement (0.57 ± 0.10 vs 0.49 ± 0.11), while preserving diagnostic accuracy. Two of the three readers detected more malignant lesions (63/69 vs 59/69 and 64/69 vs 62/69) with the AI-CAD. The AI model achieved an AUC of 0.78 (95% CI: [0.72, 0.85]; P <.001), which increased for women at screening age to 0.82 (95% CI: [0.73, 0.90]; P <.001), indicating a potential for workload reduction of 20.9% at 96% sensitivity. DISCUSSION AND CONCLUSION: Breast DWI might benefit from AI support. In our study, AI showed potential for reduction of BI-RADS-like 3 calls and increase of inter-rater agreement. However, given the limited study size, further research is needed.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Including AI in diffusion-weighted breast MRI has potential to increase reader confidence and reduce workload
Date Crossref
23/09/2025
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

MRI in cancer diagnosisRadiomics and Machine Learning in Medical ImagingDigital Radiography and Breast Imaging

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.