A Two-Point Flexion Orthosis for Proximal Interphalangeal Joint Stiffness: Simplified Traction Without Volar Obstruction

0Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Stiffness of the proximal interphalangeal (PIP) joint remains one of the most challenging conditions encountered in hand rehabilitation. When untreated or treated with delay, trauma to the PIP joint often results in progressive capsular contracture, loss of tendon gliding, and functional compromise. Although traditional orthotic management using 3-point pressure systems remains widely adopted, these devices frequently present mechanical limitations as flexion improves, particularly due to volar component impingement. This report describes a novel 2-point static progressive orthosis developed to restore PIP joint flexion without volar obstruction. The orthosis consists of a dorsal thermoplastic base anchored at the metacarpophalangeal (MCP) joint, combined with a semi-rigid dorsal ring placed on the middle phalanx (P2). A dorsal thread passing through the ring applies adjustable flexion traction through an internal-external path, avoiding the palmar side of the joint. The system eliminates the need for volar support and minimises shear forces, allowing greater flexion with increased comfort. The orthosis is fabricated in <20 minutes using low-cost materials and is indicated in patients with post-traumatic or postsurgical flexion deficits where passive range of motion exceeds 60 degrees. It is not suitable for extension contractures or night use. Clinical use suggests that this approach improves the range of motion and patient tolerance while simplifying orthotic design and monitoring. This technique may offer a practical and accessible alternative for therapists and hand surgeons managing flexion contractures of the PIP joint, particularly in cases where conventional orthoses fail due to volar interference.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A Two-Point Flexion Orthosis for Proximal Interphalangeal Joint Stiffness: Simplified Traction Without Volar Obstruction
Date Crossref
18/09/2025
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Orthopedic Surgery and RehabilitationBotulinum Toxin and Related Neurological DisordersNerve Injury and Rehabilitation

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.