Aller au contenu principal
Accès ouvert déclaré 2025 article

Real-World Effectiveness of the MiniMed™ 780G Advanced Hybrid Closed-Loop System for People ≥65 Years with Type 1 or Type 2 Diabetes in the United States

8Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : us, nl. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Objective: Multiple daily injections therapy in older adults with diabetes can negatively impact glycemic control and comorbidities. This issue may be overcome with advanced diabetes technology that reduces hypoglycemia and hyperglycemia. The present study evaluated real-world glycemic outcomes of a United States (US) cohort ≥65 years using the MiniMed™ 780G (MM780G) advanced hybrid closed-loop system. Methods: CareLink™ personal data as of December 18, 2024, for U.S. MM780G system users ≥65 years, were de-identified and analyzed. Metrics, including time in range (TIR 70–180 mg/dL), time in tight range (TITR 70–140 mg/dL), time below range 70 mg/dL (TBR70), and time above range 180 mg/dL and 250 mg/dL (TAR180 and TAR250, respectively), with and without recommended optimal settings (ROS, 100 mg/dL glucose target with 2 h active insulin time) were determined. Subanalyses based on age group (≥75 years) and type 1 diabetes (T1D) or type 2 diabetes (T2D) were, also, conducted. Results: The overall cohort ( n = 8542) had a mean TIR, TITR, TBR70, TAR180, and TAR250 of 78.4%, 51.4%, 0.9%, 20.7%, and 3.6%, respectively, with a 6.8% glucose management indicator. For ROS users ( n = 2753), TIR and TITR were higher (81.9% and 55.9%, respectively, P < 0.001), and TAR180 and TAR250 were lower (17.2% and 2.5%, respectively, P < 0.001). Data trended similarly among the population aged ≥75 years, and no differences were observed between T1D and T2D. Conclusions: In a real-world setting, a U.S. cohort aged ≥65 years using the MM780G system achieved consensus-recommended glycemic targets. Use of ROS enabled more users to achieve an even higher level of glycemic control.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Real-World Effectiveness of the MiniMed™ 780G Advanced Hybrid Closed-Loop System for People ≥65 Years with Type 1 or Type 2 Diabetes in the United States
Date Crossref
16/09/2025
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Diabetes Management and ResearchDiabetes Treatment and ManagementDiabetes and associated disorders

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.