Study on failure mechanism of ferrule sealing for fuel cell vehicles under low-temperature environment
Résumé fourni par la source
Historically, few studies have examined sealing failure in twin ferrule pipeline fittings under extreme temperatures. This research investigates their sealing performance in onboard hydrogen systems under such conditions. Experimental results revealed divergent low-temperature sealing behavior: one fitting showed no leakage, while the other leaked 100–200 ppm. Material analyses indicated that surface processing quality influences sealing but is not the decisive factor. Instead, the material mismatch between the front ferrule and the joint body was identified as the primary cause of sealing failure from room temperature to low temperature. Finite element method (FEM) simulations at 19.85°C and -40°C confirmed experimental findings. To reduce hydrogen leakage in fuel cell vehicles at low temperatures, the study recommends using consistent materials for the front ferrule and joint body.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Study on failure mechanism of ferrule sealing for fuel cell vehicles under low-temperature environment
- Date Crossref
- 10/09/2025
- Éditeur
- Informa UK Limited
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.