Customizing AI ‐based screening with real‐world data: Practical insights from diabetic retinopathy

2Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

PURPOSE: Diabetic retinopathy (DR) is a leading cause of vision loss in middle-aged adults globally. Although artificial intelligence (AI)-based screening tools like IDx-DR (classification) and Thirona RetCAD (regression) have shown high sensitivity in controlled settings, real-world screening faces challenges due to missing or low-quality images and inadequate adaptation to local healthcare needs. The objective was to compare the performance of two AI-based DR screening algorithms (IDx-DR and RetCAD) that analyse non-mydriatic images, against ophthalmologists' mydriatic fundoscopy with image analysis and the impact of customized referral threshold modification ('Greifswald modification') on screening outcomes. METHODS: This one-centre observational study included 1716 patients with diabetes mellitus (Clinical Trials Register: DRKS00035967). Sensitivity, specificity, the proportion of ungradable images and the reduction in ophthalmologic evaluations were assessed. Customized referral threshold modification was conducted using the Youden Index. RESULTS: In 98 patients (5.7%), no images could be acquired, and 35 patients (2.1%) had incomplete image sets for IDx-DR. IDx-DR rejected 438 patients (25.5%) due to image quality, while RetCAD flagged 134 eyes from 120 patients (6.9%) but provided output for all. Among analysable images, sensitivities ranged from 70.4% (RetCAD) to 93.6% (RetCAD with Greifswald modification). Including all patients reduced sensitivity from 52.7% (IDx-DR) to 79.9% (RetCAD with Greifswald modification). AI screening reduced ophthalmologic exam needs by 47.5% to 78.5%. CONCLUSIONS: Real-world DR screening performance of AI algorithms, when including non-analysable patients, can be substantially lower than in controlled studies. The use of regression algorithms enabled the customization of referral thresholds, improving screening accuracy and reducing the clinical burden.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
Customizing <scp>AI</scp> ‐based screening with real‐world data: Practical insights from diabetic retinopathy
Date Crossref
11/09/2025
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Retinal Imaging and AnalysisRetinal Diseases and TreatmentsRetinal and Optic Conditions

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.