Aller au contenu principal
Accès ouvert déclaré 2025 article

Radiographic measures of hip dysplasia correlate only moderately with computationally derived contact mechanics

0Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

ABSTRACT Hip dysplasia is currently diagnosed with two-dimensional radiographic measurements that may not adequately describe the aetiology of pain and dysfunction associated with dysplastic deformity and future osteoarthritis progression. This study aimed to assess how accurately two-dimensional radiographic measurements represent the three-dimensional mechanical joint environment. Spearman ρ correlation was used to determine associations between radiographic measurements of hip dysplasia made on pre-operative and 6-month post-operative standing AP pelvis radiographs, and hip contact stress calculated based on pre- and post-operative pelvis CT scans for a series of 100 patients (125 dysplastic hips) treated with periacetabular osteotomy using discrete element analysis. Only moderate correlations were observed between radiographic measurements and contact mechanics. Pre-operative lateral centre edge angle of Wiberg had the highest, though moderate, correlation with mean cumulative contact stress-time exposure (ρ = −0.5112, P < .0001). Tönnis angle (ρ = 0.4898, P < .0001) and extrusion index (ρ = 0.4579, P < .0001) also had moderate correlations with pre-operative mean cumulative contact stress-time exposure. Only weak correlations were found post-operatively and when comparing change in radiographic measurements to computational contact mechanics metrics before and after surgery. These findings indicate the mechanical environment of the hip joint is more complex than simple radiographic measurements that quantify coverage of the femoral head by the acetabulum. Evaluation of three-dimensional contact mechanics in dysplastic hips should be used in combination with two-dimensional radiographic evaluation for guiding clinical care for patients with hip dysplasia.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Radiographic measures of hip dysplasia correlate only moderately with computationally derived contact mechanics
Date Crossref
05/09/2025
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Hip disorders and treatmentsOrthopaedic implants and arthroplastyHip and Femur Fractures

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.