Résumé fourni par la source

OBJECTIVES: Accurate diagnosis of biliary strictures remains challenging. This study aimed to develop an artificial intelligence (AI) system for peroral cholangioscopy (POCS) using a Vision Transformer (ViT) architecture and to evaluate its performance compared to different vendor devices, conventional convolutional neural networks (CNNs), and endoscopists. METHODS: We retrospectively analyzed 125 patients with indeterminate biliary strictures who underwent POCS between 2012 and 2024. AI models including the ViT architecture and two established CNN architectures were developed using images from CHF-B260 or B290 (CHF group; Olympus Medical) and SpyScope DS or DS II (Spy group; Boston Scientific) systems via a patient-level, 3-fold cross-validation. For a direct comparison against endoscopists, a balanced 440-image test set, containing an equal number of images from each vendor, was used for a blinded evaluation. RESULTS: The 3-fold cross-validation on the entire 2062-image dataset yielded a robust accuracy of 83.9% (95% confidence interval (CI), 80.9-86.7) for the ViT model. The model's accuracy was consistent between CHF (82.7%) and Spy (86.8%, p = 0.198) groups, and its performance was comparable to the evaluated conventional CNNs. On the 440-image test set, the ViT's accuracy of 78.4% (95% CI, 72.5-83.8) was comparable to that of expert endoscopists (82.0%, p = 0.148) and non-experts (73.0%, p = 0.066), with no statistically significant differences observed. CONCLUSIONS: The novel ViT-based AI model demonstrated high vendor-agnostic diagnostic accuracy across multiple POCS systems, achieving performance comparable to conventional CNNs and endoscopists evaluated in this study.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Vendor‐Agnostic Vision Transformer‐Based Artificial Intelligence for Peroral Cholangioscopy: Diagnostic Performance in Biliary Strictures Compared With Convolutional Neural Networks and Endoscopists
Date Crossref
03/09/2025
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Gallbladder and Bile Duct DisordersGastrointestinal Bleeding Diagnosis and TreatmentEsophageal and GI Pathology

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.