Impact of obesity on palpation-guided distal radial access for coronary procedures: subgroup analysis of the multicenter, prospective KODRA registry
Rattachement africain : kr. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: There is limited data on the impact of body mass index (BMI) on distal radial access (DRA). Using a large-scale prospective registry, the influence of obesity on DRA outcomes was evaluated, including cannulation and complications. METHODS: Using data from the prospective, multicenter KODRA (Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach) registry data, 4,638 patients who planned palpation-guided distal radial artery puncture were enrolled into two groups, both with body mass index (BMI) information available: obese (n = 2,205; BMI ≥ 25 kg/m²) and non-obese (n = 2,433). The primary endpoint was the success rate of distal radial artery cannulation. Secondary endpoints included cannulation time, crossover rate, and DRA-related complications. RESULTS: The mean age was 66.6 ± 11.7 years and 67.2% were men. No significant difference existed in the success rate of distal radial artery cannulation between the two groups (94.5% in the obese group vs. 94.3% in the non-obese group, p = 0.787). This tendency in cannulation success rate was consistently observed in multiple sensitivity analyses, including multivariable and propensity score-matched analyses. Crossover rate (6.6% vs. 6.7%, p = 0.962) and DRA-related complications (4.3% vs. 4.6%, p = 0.630) were not significantly different between groups. However, cannulation time was significantly longer in the obese group compared to the non-obese group [105 (101-109) sec vs. 100 (97-103) sec, p = 0.046]. CONCLUSIONS: In this subgroup analysis of the KODRA registry, obesity was not associated with the success rate for palpation-guided distal radial artery cannulation, crossover rate, and DRA-related complications.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Impact of obesity on palpation-guided distal radial access for coronary procedures: subgroup analysis of the multicenter, prospective KODRA registry
- Date Crossref
- 29/12/2025
- Éditeur
- VM Media Group sp. z o.o
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.