Aller au contenu principal
Accès ouvert déclaré 2025 article

Evaluation of SARS-CoV-2 lateral flow device sensitivity: a comparison of systematic laboratory assessments with manufacturer-reported sensitivity

0Citations signalées, ce qui n’est pas une note de qualité
10Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : gb, mv. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background: Self-testing for SARS-CoV-2 infection using lateral flow devices (LFDs) was a key component of the COVID-19 pandemic response; however, LFD performance has shown a high degree of variability. Between August 2020 and July 2023, the UK Health Security Agency (UKHSA), including predecessor organisations, undertook a three-phase SARS-CoV-2 test development and evaluation programme to independently evaluate commercially available SARS-CoV-2 LFDs, incorporating standardised laboratory assessment of test sensitivity. Here we describe results from a comparison of UKHSA laboratory assessment findings with manufacturer-reported LFD sensitivity data. Methods: ]/mL]) from LFD instructions for use (IFU). Findings: UKHSA-determined LFD sensitivity ranged from 32 to 83%. Of 86 LFDs assessed, 73 included device sensitivity data in the manufacturers' IFU that claimed clinical sensitivity ≥85%, and 49 claimed clinical sensitivity ≥95%. No evidence of correlation was observed between manufacturer-reported test sensitivity and UKHSA determined test sensitivity, and no evidence of correlation was observed between manufacturer-reported test LOD and UKHSA-determined test sensitivity. Interpretation: Laboratory evaluation found no evidence of correlation between manufacturer-reported SARS-CoV-2 LFD sensitivity data and UKHSA laboratory-determined sensitivity, supporting previous reports of discrepancies. Our findings suggest that manufacturer-reported performance data and claims for SARS-CoV-2 LFDs should be interpreted with caution and support the need for independent monitoring and testing, and standardisation of analysis methodologies. Funding: This study was funded by UK Department of Health and Social Care; UK Health Security Agency (formerly Public Health England and the National Health Service Test and Trace); and the University of Oxford NIHR Biomedical Research Centre.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Evaluation of SARS-CoV-2 lateral flow device sensitivity: a comparison of systematic laboratory assessments with manufacturer-reported sensitivity
Date Crossref
01/09/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

SARS-CoV-2 detection and testingInfection Control and VentilationSARS-CoV-2 and COVID-19 Research

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.