Aller au contenu principal
2025 article

Comparison of the Diagnostic Utility of Computed Tomography Angiography Head With and Without 3-Dimensional Volume-Rendered Images for Aneurysm Detection in Subarachnoid Hemorrhage Patients Versus Digital Subtraction Angiography

1Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND AND OBJECTIVES: Generating computed tomography (CT) angiography (CTA) 3-dimensional (3D) volume-rendered (3DVR) images can be time consuming without specialized technical staff or artificial intelligence solutions. However, their role in aneurysm detection in patients with subarachnoid hemorrhage is not known. Our aim was to assess the diagnostic utility of 64-detector row CTA with 3DVR (CTA+3DVR) vs without 3DVR (CTA-3DVR) in intracranial aneurysm detection. METHODS: A retrospective analysis of patients presenting with spontaneous subarachnoid hemorrhage (regardless of location) who underwent 64-detector row CTA and subsequent digital subtraction angiography (DSA) between 2013 and 2020 was performed. DSA was the reference standard. Almost all DSAs were performed with 3D rotational angiography. Two neuroradiologists blinded to the DSA results separately reviewed CTA source and maximum intensity projection images without 3DVR images (CTA-3DVR) and then immediately followed by the 3DVR images (CTA + 3DVR). Disagreements were resolved by consensus review. Aneurysm size was measured on DSA. RESULTS: In total, 200 patients were included in the study. 140 aneurysms in 114 patients were detected on DSA. CTA-3DVR detected 135 of 140 aneurysms (96.4%), and CTA+3DVR detected 136 of 140 aneurysms (97.1%). All missed aneurysms measured 2-4 mm. Three of four missed aneurysms were associated with multiple aneurysms, and 1 was a singly occurring, 2-mm M3 segment aneurysm. The 1 additional aneurysm detected by CTA + 3DVR was a 3-mm left A3 segment aneurysm. No false positives occurred with or without 3DVR. CONCLUSION: CTA+3DVR detected 1 additional distal A3 aneurysm vs CTA-VR. 3DVR does not seem to substantially improve the detection of aneurysms but may be useful in the emergent setting for aneurysm morphology characterization.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comparison of the Diagnostic Utility of Computed Tomography Angiography Head With and Without 3-Dimensional Volume-Rendered Images for Aneurysm Detection in Subarachnoid Hemorrhage Patients Versus Digital Subtraction Angiography
Date Crossref
28/08/2025
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Intracranial Aneurysms: Treatment and ComplicationsDigital Image Processing TechniquesAnatomy and Medical Technology

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.