From Volume to Mass: Transforming Volatile Organic Compound Detection with Photoionization Detectors and Machine Learning

2Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

(1) Objective: Volatile organic compounds (VOCs) monitoring in industrial parks is crucial for environmental regulation and public health protection. However, current techniques face challenges related to cost and real-time performance. This study aims to develop a dynamic calibration framework for accurate real-time conversion of VOCs volume fractions (nmol mol−1) to mass concentrations (μg m−3) in industrial environments, addressing the limitations of conventional monitoring methods such as high costs and delayed response times. (2) Methods: By innovatively integrating photoionization detector (PID) with machine learning, we developed a robust conversion model utilizing PID signals, meteorological data, and a random forest’s (RF) algorithm. The system’s performance was rigorously evaluated against standard gas chromatography-flame ionization detectors (GC-FID) measurements. (3) Results: The proposed framework demonstrated superior performance, achieving a coefficient of determination (R2) of 0.81, root mean squared error (RMSE) of 48.23 μg m−3, symmetric mean absolute percentage error (SMAPE) of 62.47%, and a normalized RMSE (RMSEnorm) of 2.07%, outperforming conventional methods. This framework not only achieved minute-level response times but also reduced costs to just 10% of those associated with GC-FID methods. Additionally, the model exhibited strong cross-site robustness with R2 values ranging from 0.68 to 0.69, although its accuracy was somewhat reduced for high-concentration samples (>1500 μg m−3), where the mean absolute percentage error (MAPE) was 17.8%. The inclusion of SMAPE and RMSEnorm provides a more nuanced understanding of the model’s performance, particularly in the context of skewed or heteroscedastic data distributions, thereby offering a more comprehensive assessment of the framework’s effectiveness. (4) Conclusions: The framework’s innovative combination of PID’s real-time capability and RF’s nonlinear modeling achieves accurate mass concentration conversion (R2 = 0.81) while maintaining a 95% faster response and 90% cost reduction compared to GC-FID systems. Compared with traditional single-coefficient PID calibration, this framework significantly improves accuracy and adaptability under dynamic industrial conditions. Future work will apply transfer learning to improve high-concentration detection for pollution tracing and environmental governance in industrial parks.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
From Volume to Mass: Transforming Volatile Organic Compound Detection with Photoionization Detectors and Machine Learning
Date Crossref
27/08/2025
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced Chemical Sensor TechnologiesAir Quality Monitoring and ForecastingWater Quality Monitoring and Analysis

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.