Aller au contenu principal
Accès ouvert déclaré 2025 preprint

Generalization of Optimal Control Saturation Pulse Design for Robust and High CEST Contrast

1Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : at, de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Purpose Optimal Control (OC) CEST pulse design for singular pulses that can be used flexibly and robustly with high saturation at different duty cycles, saturation durations and magnetic field strengths. Theory and Methods An OC framework was developed to design a single pulse shape that can be flexibly applied for arbitrary pulse train parameters and outperform typically used CEST saturation pulses shapes. The pulse design was developed primarily with a continuous wave spectrum (CW) as the optimization target, but can be easily adapted to specific scenarios. The generalized OC pulse was evaluated through simulations, phantom, and in vivo measurements on a 3 T clinical scanner. Performance was assessed in terms of contrast, robustness to field inhomogeneities, and resilience against artifacts such as Rabi oscillations and sidebands, compared to established saturation techniques. Results Investigations showed that the generalized OC pulse achieved a contrast matching CW saturation and also functioned well under field inhomogeneities. Low-pass filtering of the optimized pulse shape effectively suppressed artifacts outside the initial optimization frequency range, enabling generalization across different field strengths. Phantom experiments consistently showed higher contrast than Gaussian, Fermi, and adiabatic spin-lock pulses for various CEST agents covering most clinically relevant regimes. In vivo imaging demonstrated substantially enhanced CEST contrast for both creatine/phosphocreatine in muscle and Amide Proton Transfer (APT) in brain compared to Gaussian saturation. Conclusion The generalized OC pulse provides a robust and flexible alternative to conventional CEST saturation strategies. Its integration into the open-source Pulseq-CEST framework supports simple reproducibility and a vendor-independent implementation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Generalization of Optimal Control Saturation Pulse Design for Robust and High CEST Contrast
Date Crossref
25/08/2025
Éditeur
openRxiv
Type
posted-content

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Non-Destructive Testing TechniquesAdvanced Surface Polishing Techniques

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.