Comparing respiratory-triggered T2WI MRI with an artificial intelligence-assisted technique and motion-suppressed respiratory-triggered T2WI in abdominal imaging

1Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background: Magnetic resonance imaging (MRI) plays a crucial role in the diagnosis of abdominal conditions. A comprehensive assessment, especially of the liver, requires multi-planar T2-weighted sequences. To mitigate the effect of respiratory motion on image quality, the combination of acquisition and reconstruction with motion suppression (ARMS) and respiratory triggering (RT) is commonly employed. While this method maintains image quality, it does so at the expense of longer acquisition times. We evaluated the effectiveness of free-breathing, artificial intelligence-assisted compressed-sensing respiratory-triggered T2-weighted imaging (ACS-RT T2WI) compared to conventional acquisition and reconstruction with motion-suppression respiratory-triggered T2-weighted imaging (ARMS-RT T2WI) in abdominal MRI, assessing both qualitative and quantitative measures of image quality and lesion detection. Methods: In this retrospective study, 334 patients with upper abdominal discomfort were examined on a 3.0T MRI system. Each patient underwent both ARMS-RT T2WI and ACS-RT T2WI. Image quality was analyzed by two independent readers using a five-point Likert scale. The quantitative measurements included the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), peak signal-to-noise ratio (PSNR), and sharpness. Lesion detection rates and contrast ratios (CRs) were also evaluated for liver, biliary system, and pancreatic lesions. Results: 0.43±0.17), but no significant difference was found in others like focal nodular hyperplasia (FNH), hepatapostema, hepatocellular carcinoma (HCC), cholangiocarcinoma, metastatic tumors, and biliary calculus. Conclusions: ACS-RT T2WI ensures clinical reliability with a substantial scan time reduction (>80%). Despite minor losses in detail and SNR reduction, ACS-RT T2WI does not impair lesion detection, marking its efficacy in abdominal imaging.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comparing respiratory-triggered T2WI MRI with an artificial intelligence-assisted technique and motion-suppressed respiratory-triggered T2WI in abdominal imaging
Date Crossref
01/09/2025
Éditeur
AME Publishing Company
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

MRI in cancer diagnosisAdvanced MRI Techniques and ApplicationsHepatocellular Carcinoma Treatment and Prognosis

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.