Aller au contenu principal
Accès ouvert déclaré 2025 article

Near Visual Acuity Measurements by Community Screeners Using Digital (Peek) Testing Versus Conventional Charts in India

0Citations signalées — pas une note de qualité
6Institutions déclarées
4Pays d’affiliation déclarés

Résumé fourni par la source

Purpose: The Peek digital near vision test has been previously validated in a trial setting; here it is assessed in clinic (stage 1) and community (stage 2) settings. Methods: The study was carried out in the catchment area of Dr. Shroff's Charity Eye Hospital, Mohammadi, Uttar Pradesh, India, with a total of 768 participants. Stage 1 assessed the interobserver variability of Peek near vision impairment (NVI) screening in 168 clinic participants, with three trained community screeners. Stage 2 compared Peek to conventional chart testing for NVI screening using Cohen's kappa coefficient, sensitivity, and specificity and, for quantitative near visual acuity (NVA) measurement, using Bland-Altman limits of agreement (LoA) in 600 participants with two screeners. Results: In stage 1, interobserver variability using Peek ranged from 96.43% to 98.21% (kappa = 0.92-0.96). In stage 2, there was overall agreement in 95.8% of cases (kappa = 0.91). Peek testing had a sensitivity and specificity of 91.25% (95% confidence interval [CI], 87.22-94.1) and 99.41% (95% CI, 97.86-99.84), respectively. For NVA testing, the 95% LoA between Peek and chart testing were within -0.11 and +0.07 logMAR. Mean test time was 40.3 seconds (95% CI, 38.8-41.7) for Peek versus 46.6 seconds (95% CI, 45.5-47.7) for a conventional chart. Conclusions: The previously demonstrated validity of Peek testing was maintained when used by trained community screeners. Translational Relevance: The Peek near vision test can be used as a validated method of NVA/NVI measurement in research, clinical and community settings.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Near Visual Acuity Measurements by Community Screeners Using Digital (Peek) Testing Versus Conventional Charts in India
Date Crossref
19/08/2025
Éditeur
Association for Research in Vision and Ophthalmology (ARVO)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Ophthalmology and Visual Impairment StudiesGlaucoma and retinal disordersVisual perception and processing mechanisms

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.